User name Boeglin
Log entry time 16:07:57 on April 6,2012
Entry number 370815
keyword=Day shift summary
8:00 continue prod. run 22816/6793/40871
8:27 finish runs, next dilution runs
8:34 Carbon C12-40
8:43 Dummy target in place, no beam (RF promlems) expected delay 15 min
9:15 beam back continue with dilution on dummy target
9:30 finished dilution runs with home position, switch to new kinematics
10:00 Target magnet quench
11:10 Hall back in power permit. Getting ready for tuning
11:27 Problem with resetting the FSD trip due to the target magnet.
Require a controlled access to check the system.
11:45 access finished, no problem found => software problem in MCC ?
11:28 decided to skip Moeller and get ready for beam recovery for production
13:15 start beam recovery
13:50 beam recovery completed, polarizing target
15:00 polarization complete: 44.8%
15:04 start poduction running on new kinematics p = 1.496 GeV/c
Dilution runs p = 1.608
Carbon 12C-40: 3794/22817
Dummy : 3786/22819
Home/empty: 3787/22820
Production runs p = 1.496
3808/22831/40881 18M events
3809/22832/40882 4M events (ended early due to 1/2 wave plate change)