Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry
,
Make Followup Entry
User name Sasha
Log entry time 23:55:36 on April 10, 2012
Entry number 372508
keyword=Moller results
Moller results on April 10 19:25 - 23:35
Crew: Sasha, Roman, Vadym, Jixie
Beam energy was 1.70669GeV(set point)?.
Helicity frequency 960Hz, 8 Windows Qartet.
Wien filter angle is 90.0 88.712, -49.6°
The raster was OFF. The half wave plate was IN. Passive HWP was IN.
Beam tuning took ~1 hour.
Runs 15295-15303 - detector HV tunning
Runs 15304-15313 - beam polarization measurement (Target 2).
Runs 15314-15317 - bleed-through measurement Hall A laser OFF, slit is -1.0(full open)
Runs 15318-15327 - Q1 scan (50nA)
Runs 15328-15335 - Q3 scan (50nA)
Preliminary results
#
Wien angle
beam
runs
target
P
beam
%
comments
1
-49.6°
0.1 µA
15304-15313
2
-88.18±0.30
Slit=14.0
2
-49.6°
0.0 µA
15314-15317
2
-2.6±2.6
Hall A laser OFF, Slit=-1.0
A copy of this log entry has been emailed to: gen@jlab.org, gomez@jlab.org
Figure 1
Figure 2