• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 04:01:23 on April 12, 2012

    Entry number 373033

    keyword=End_of_Run_23177
    ****************************
     Run Number: 23177
     End of Run Comment:
    Run_type=Optics,target_type=C12_40,comment_text=delta scan RHRS -3.5%, no LHRS
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=0   ps4=0   ps5=0   ps6=0   ps7=0   ps8=100   
    
    EVENTS   : 301771       
    
    TIME     : 3.464 mins  
    
    DEAD TIME:   7.53%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1:1542.7/1542.7 Hz   T2:T2:17.5/17.5 Hz   T3:T3: 0.0/2459.1 Hz   T4:T4: 0.0/30.4 Hz   T5:T5: 0.0/0.0  Hz   T6:T6: 0.0/0.0  Hz   T7:T7: 0.0/103852.3 Hz   T8:T8:10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1: 320626/320626   T2:T2:   3638/3638     T3:T3:      0/511089   T4:T4:      0/6312     T5:T5:      0/0        T6:T6:      0/0        T7:T7:      0/21584130  T8:T8:   2128/212823   
    
    AVERAGE CURRENT
    BCM 1 : -0.0010uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -3.32924 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : -0.1972        
    BCM d1 : -0.2067        
    
    
    ****************************
    End-of-run EPICS data for Run Number 23177 at Thu Apr 12 04:01:20 EDT 2012
    
    

    Target Info

    Target number in beam : 6 Target encoder position : 12418 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 2.49865 Magnet Current : 60.882 VPT 3He (K) : 1.36397 VPT 4He (K) : 1.39157 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 1710.59 Beam Current : 0.0554229 Beam Current (Hall C) : 90.24 Left arm angle : -0.179 Left arm momentum : 1.72197 Right arm angle : 0.197 Right arm momentum : 1.76483 Left septum current : 543.172 Right septum current : 737.652

    Misc Epics Info

    ----- Left Arm Q1 momentum : 1.72194 Left Arm Q1 power supply : 879.66 Left Arm Q1 gauss meter : -0.07322 Left Arm Q2 gauss meter : 0.3715 Left Arm Q2 power supply current : 701.683 Left Arm Q2 momentum : 1.72177 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 576.726 Left Arm D1 momentum : 1.72197 Left Arm D1 NMR : 0.637252 Left Arm Q3 gauss meter : -0.41934 Left Arm Q3 power supply current : 830.764 Left Arm Q3 momentum : 1.72188 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.76497 Right Arm Q1 power supply : 896.109 Right Arm Q1 gauss meter : -0.022412 Right Arm Q2 power supply current : 721.23 Right Arm Q2 momentum : 1.76528 Right Arm Q2 gauss meter : 0.3799 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 609.117 Right Arm D1 momentum : 1.76483 Right Arm D1 NMR : 0.654908 Right Arm Q3 power supply current : 850.128 Right Arm Q3 momentum : 1.76534 Right Arm Q3 gauss meter : 0.377 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 88.7125 Wien BDL (First Solenoid) (Gcm) : 1239.7 Wien BDL (Second Solenoid) (Gcm) : 729.5 Wien angle (Horizontal) : -49.5997 Wien BDL (Gcm) : -1432.5 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 226 Laser power Hall A : 0 Rotating waveplate : 3496 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 543.193 Right Septum Magnet Current : 737.652 -----