NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 06:24:56 on April 13, 2012
Entry number 373688
keyword=End_of_Run_4289
****************************
Run Number: 4289
End of Run Comment:
Run_type=Dilution,target_type=C12_40 top,comment_text=Po = 1.494 GeV/c
PRESCALE FACTORS:ps1=0 ps2=0 ps3=6 ps4=14 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : 1092832
TIME : 6.841 mins
DEAD TIME: 0.66%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/14777.3 Hz T2:T2: 0.0/229.5 Hz T3:T3:2660.9/15965.7 Hz T4:T4:19.4/271.2 Hz T5:T5: 0.0/25212.7 Hz T6:T6: 0.0/23630.0 Hz T7:T7: 0.0/103908.3 Hz T8:T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/6065364 T2:T2: 0/94186 T3:T3:1092188/6553133 T4:T4: 7949/111295 T5:T5: 0/10348577 T6:T6: 0/9698981 T7:T7: 0/42649269 T8:T8: 0/420302
AVERAGE CURRENT
BCM 1 : 0.0639 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.85946 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 26.11
BCM d1 : 26.35
****************************
End-of-run EPICS data for Run Number 4289 at Fri Apr 13 06:24:52 EDT 2012
Target Info
Target number in beam : 6
Target encoder position : 12418
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 2.49865
Magnet Current : 60.882
VPT 3He (K) : 0.952587
VPT 4He (K) : 0.962315
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 1710.61
Beam Current : 0.0563151
Beam Current (Hall C) : 100.11
Left arm angle : -0.179
Left arm momentum : 1.49399
Right arm angle : 0.197
Right arm momentum : 1.49402
Left septum current : 500.107
Right septum current : 660.97
Misc Epics Info
-----
Left Arm Q1 momentum : 1.49393
Left Arm Q1 power supply : 763.18
Left Arm Q1 gauss meter : -0.0635
Left Arm Q2 gauss meter : 0.3226
Left Arm Q2 power supply current : 609.052
Left Arm Q2 momentum : 1.49448
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 497.585
Left Arm D1 momentum : 1.49398
Left Arm D1 NMR : 0.552939
Left Arm Q3 gauss meter : -0.36391
Left Arm Q3 power supply current : 720.85
Left Arm Q3 momentum : 1.49407
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.4939
Right Arm Q1 power supply : 758.48
Right Arm Q1 gauss meter : -0.019035
Right Arm Q2 power supply current : 610.34
Right Arm Q2 momentum : 1.49386
Right Arm Q2 gauss meter : 0.3215
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 512.06
Right Arm D1 momentum : 1.49402
Right Arm D1 NMR : 0.554414
Right Arm Q3 power supply current : 719.493
Right Arm Q3 momentum : 1.49407
Right Arm Q3 gauss meter : 0.3191
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -49.5997
Wien BDL (Gcm) : -1432.5
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 212
Laser power Hall A : 0
Rotating waveplate : 7511
Fake Half-Wave Plate (8960=OUT) : 13056
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 500.107
Right Septum Magnet Current : 660.97
-----