This afternoon, we found that the right arm septa current is a little mismatch from table and that calculated from script "GetSeptaCurrent". After talking with Jixie, I updated the septa current table which put beside the screen of the shift leader`s computer. I also found that the runplan have this table. We need to update it too.
Figure 1
Septa Current Match the Dipole Momentum.pdf