Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name R. Michaels
Log entry time 07:46:19 on April15,2012
Entry number 374802
Followups:
keyword=run number failed to increment
This time on the R-HRS DAQ, the run number in the runcontrol GUI
failed to increment. It shows 23386. But we are writing to run
23387, as expected.
Notice that the Output File in runcontrol says its run 23387.
It looks like a casualty of the "too many databases" problem.
One database for runcontrol and another for the rest of CODA.
They can get out of synch.
Doing a kcoda/startcoda should fix this.
Fig 1 -- runcontrol GUI
Fig 2 -- info about the files. they seem ok.
After this run, we will "startcoda" for R-HRS.
This is a different disease from earlier when we had duplicate
files. But maybe it is related ?
FIGURE 1
FIGURE 2