Log entry time 13:09:17 on April 17, 2012
Entry number 375869
keyword=End_of_Run_4583
****************************
Run Number: 4583
End of Run Comment:
Run_type=Optics,target_type=NH3 bottom,comment_text=p0=1.691,slow raster 1cm fast Raster 1x1
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 195)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 4583 at Tue Apr 17 13:09:11 EDT 2012
Target Info
Target number in beam : 7
Target encoder position : 155
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 999
Magnet Current : 999
VPT 3He (K) : 0
VPT 4He (K) : 0
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 1708.35
Beam Current : -0.000170083
Beam Current (Hall C) : 89.07
Left arm angle : -0.179
Left arm momentum : 0.0030724
Right arm angle : 0.197
Right arm momentum : 0.0355626
Left septum current : 0
Right septum current : 0
Misc Epics Info
-----
Left Arm Q1 momentum : 0.00323878
Left Arm Q1 power supply : 0.480659
Left Arm Q1 gauss meter : 0.000102
Left Arm Q2 gauss meter : 0.001092
Left Arm Q2 power supply current : 0.000198421
Left Arm Q2 momentum : 0.00414471
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -2.02781
Left Arm D1 momentum : 0.0030724
Left Arm D1 NMR : 0.383636
Left Arm Q3 gauss meter : -0.153412
Left Arm Q3 power supply current : 303.982
Left Arm Q3 momentum : 0.630049
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.00773595
Right Arm Q1 power supply : 1.06813
Right Arm Q1 gauss meter : -0.0001659
Right Arm Q2 power supply current : -0.00280946
Right Arm Q2 momentum : -6.87641e-06
Right Arm Q2 gauss meter : 0.0002567
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 2.07788
Right Arm D1 momentum : 0.0355626
Right Arm D1 NMR : 0.161676
Right Arm Q3 power supply current : -0.00288816
Right Arm Q3 momentum : -5.99744e-06
Right Arm Q3 gauss meter : 0.0002538
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -49.5997
Wien BDL (Gcm) : -1432.5
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 221
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 0
Right Septum Magnet Current : 0
-----