NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 16:35:26 on April 22, 2012
Entry number 377553
keyword=End_of_Run_4854
****************************
Run Number: 4854
End of Run Comment:
Run_type=Production,target_type=NH3 top,comment_text=0.9561,HWP IN
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 195)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 4854 at Sun Apr 22 16:35:19 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 50886
uWave Frequency (Ghz) : 69994.1
RF Frequency (Mhz) : 106.5
Magnetic Field (T) : 2.49865
Magnet Current : 60.882
VPT 3He (K) : 1.16207
VPT 4He (K) : 1.14355
NMR Area : -8.68249
Polarization : 30.0697
General Run Info
Beam energy (MeV) : 1157.16
Beam Current : 0.0504926
Beam Current (Hall C) : 150.54
Left arm angle : -0.179
Left arm momentum : 0.956087
Right arm angle : 0.197
Right arm momentum : 0.956119
Left septum current : 300.591
Right septum current : 394.525
Misc Epics Info
-----
Left Arm Q1 momentum : 0.955845
Left Arm Q1 power supply : 488.35
Left Arm Q1 gauss meter : -0.04064
Left Arm Q2 gauss meter : 0.2067
Left Arm Q2 power supply current : 389.618
Left Arm Q2 momentum : 0.956033
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 316.209
Left Arm D1 momentum : 0.956086
Left Arm D1 NMR : 0.353983
Left Arm Q3 gauss meter : -0.23296
Left Arm Q3 power supply current : 461.337
Left Arm Q3 momentum : 0.95619
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.955958
Right Arm Q1 power supply : 485.359
Right Arm Q1 gauss meter : -0.01223
Right Arm Q2 power supply current : 390.586
Right Arm Q2 momentum : 0.955995
Right Arm Q2 gauss meter : 0.2051
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 326.595
Right Arm D1 momentum : 0.956119
Right Arm D1 NMR : 0.354803
Right Arm Q3 power supply current : 460.384
Right Arm Q3 momentum : 0.956015
Right Arm Q3 gauss meter : 0.2043
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -69.9998
Wien BDL (Gcm) : -2020.7
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 124
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 300.549
Right Septum Magnet Current : 394.509
-----