    User name kamyers

    Log entry time 03:08:50 on April26,2012

    Entry number 379204

    keyword=LHRS Q1 fluctuations, unresolved

    Have been unable to resolve the fluctuations in the left Q1 current/momentum. Things I tried:

    Turning off regulation, set current 5 A above setpoint, turn regulation back on

    Turning off regulation, set current 5 A below setpoint, turn regulation back on

    Moving entire left arm to 0.9 and back to 0.8703

    the frequent "magnet mismatch" state was not present at the previous momentum setting (first figure). The fluctuation in momentum is +-0.1% (0.8703 -> 0.8715), small, so we are probably ok. But should be investigated in the morning I guess.