• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:26:05 on April 26, 2012

    Entry number 379371

    keyword=End_of_Run_23964
    ****************************
     Run Number: 23964
     End of Run Comment:
    Run_type=Other,target_type=NH3 top,comment_text=DAQ TEST, Raster on, RHRS p0 = 0.8703 GeV, HW plate is out,bpm calibration
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 185)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 23964 at Thu Apr 26 19:26:01 EDT 2012
    
    

    Target Info

    Target number in beam : 7 Target encoder position : 11 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 2.49795 Magnet Current : 60.865 VPT 3He (K) : 0.944596 VPT 4He (K) : 0.997565 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 1157.78 Beam Current : 0.0569201 Beam Current (Hall C) : 88.53 Left arm angle : -0.179 Left arm momentum : 1.15113 Right arm angle : 0.197 Right arm momentum : 0.870305 Left septum current : 362.01 Right septum current : 359.293

    Misc Epics Info

    ----- Left Arm Q1 momentum : 1.15051 Left Arm Q1 power supply : 587.793 Left Arm Q1 gauss meter : -0.0488 Left Arm Q2 gauss meter : 0.2487 Left Arm Q2 power supply current : 469.131 Left Arm Q2 momentum : 1.15114 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 382.476 Left Arm D1 momentum : 1.15113 Left Arm D1 NMR : 0.426147 Left Arm Q3 gauss meter : -0.28043 Left Arm Q3 power supply current : 555.347 Left Arm Q3 momentum : 1.15104 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 0.870229 Right Arm Q1 power supply : 441.833 Right Arm Q1 gauss meter : -0.011125 Right Arm Q2 power supply current : 355.538 Right Arm Q2 momentum : 0.870211 Right Arm Q2 gauss meter : 0.18736 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 297.427 Right Arm D1 momentum : 0.870305 Right Arm D1 NMR : 0.32296 Right Arm Q3 power supply current : 419.072 Right Arm Q3 momentum : 0.870228 Right Arm Q3 gauss meter : 0.18596 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -69.9998 Wien BDL (Gcm) : -2020.7 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 131 Laser power Hall A : 0 Rotating waveplate : 7511 Fake Half-Wave Plate (8960=OUT) : 13056 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 361.883 Right Septum Magnet Current : 359.293 -----