NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 23:13:20 on April 26, 2012
Entry number 379427
keyword=End_of_Run_5113
****************************
Run Number: 5113
End of Run Comment:
Run_type=Spot++,target_type=Carbon hole,comment_text=DAQ TEST, slow Raster on, LHRS p0 = 0.8703 GeV, HW plate is out, spot++
PRESCALE FACTORS:ps1=0 ps2=0 ps3=2 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : 1892327
TIME : 3.889 mins
DEAD TIME: 88.76%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/6584.7 Hz T2:T2: 0.0/80.0 Hz T3:T3:72189.7/144379.5 Hz T4:T4: 0.0/201.2 Hz T5:T5: 0.0/148984.0 Hz T6:T6: 0.0/174287.7 Hz T7:T7: 0.0/103919.2 Hz T8:T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/1536278 T2:T2: 0/18671 T3:T3:16842624/33685248 T4:T4: 0/46950 T5:T5: 0/34759544 T6:T6: 0/40663163 T7:T7: 0/24245438 T8:T8: 0/238910
AVERAGE CURRENT
BCM 1 : 0.0107 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.70689 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 2.422
BCM d1 : 2.591
****************************
End-of-run EPICS data for Run Number 5113 at Thu Apr 26 23:13:15 EDT 2012
Target Info
Target number in beam : 2
Target encoder position : 41905
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 2.49795
Magnet Current : 60.865
VPT 3He (K) : 0.946782
VPT 4He (K) : 1.00944
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 1156.7
Beam Current : -8.2307e-05
Beam Current (Hall C) : 154.74
Left arm angle : -0.179
Left arm momentum : 1.15113
Right arm angle : 0.197
Right arm momentum : 0.870306
Left septum current : 361.841
Right septum current : 359.309
Misc Epics Info
-----
Left Arm Q1 momentum : 1.15061
Left Arm Q1 power supply : 587.793
Left Arm Q1 gauss meter : -0.04881
Left Arm Q2 gauss meter : 0.2487
Left Arm Q2 power supply current : 469.136
Left Arm Q2 momentum : 1.15115
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 382.474
Left Arm D1 momentum : 1.15113
Left Arm D1 NMR : 0.426146
Left Arm Q3 gauss meter : -0.28037
Left Arm Q3 power supply current : 555.349
Left Arm Q3 momentum : 1.15104
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.870229
Right Arm Q1 power supply : 441.833
Right Arm Q1 gauss meter : -0.011139
Right Arm Q2 power supply current : 355.54
Right Arm Q2 momentum : 0.870215
Right Arm Q2 gauss meter : 0.18735
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 297.429
Right Arm D1 momentum : 0.870305
Right Arm D1 NMR : 0.32296
Right Arm Q3 power supply current : 419.074
Right Arm Q3 momentum : 0.870234
Right Arm Q3 gauss meter : 0.18597
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -69.9998
Wien BDL (Gcm) : -2020.7
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 103
Laser power Hall A : 0
Rotating waveplate : 7511
Fake Half-Wave Plate (8960=OUT) : 13056
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 361.841
Right Septum Magnet Current : 359.293
-----