• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:58:24 on May 3, 2012

    Entry number 381995

    keyword=End_of_Run_5590
    ****************************
     Run Number: 5590
     End of Run Comment:
    Run_type=Optics,target_type=C12_40,comment_text=Delta Scan 3%, No LHe
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=1   ps4=0   ps5=0   ps6=0   ps7=0   ps8=0   
    
    EVENTS   : 501625       
    
    TIME     : 7.382 mins  
    
    DEAD TIME:   6.17%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/1429.7 Hz   T2:T2: 0.0/17.1 Hz   T3:T3:1207.1/1207.1 Hz   T4:T4: 0.0/14.0 Hz   T5:T5: 0.0/2128.3 Hz   T6:T6: 0.0/5580.4 Hz   T7:T7: 0.0/103929.2 Hz   T8:T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/633252   T2:T2:      0/7561     T3:T3: 534674/534674   T4:T4:      0/6204     T5:T5:      0/942714   T6:T6:      0/2471742  T7:T7:      0/46033958  T8:T8:      0/453566   
    
    AVERAGE CURRENT
    BCM 1 : 0.0481 uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.71239 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 20.67          
    BCM d1 : 21.94          
    
    
    ****************************
    End-of-run EPICS data for Run Number 5590 at Thu May 3 19:58:18 EDT 2012
    
    

    Target Info

    Target number in beam : 6 Target encoder position : 12391 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 999 Magnet Current : 999 VPT 3He (K) : 0 VPT 4He (K) : 1.49448 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 2253.83 Beam Current : 0.0512133 Beam Current (Hall C) : 179.04 Left arm angle : -0.179 Left arm momentum : 2.18296 Right arm angle : 0.197 Right arm momentum : 1.73477 Left septum current : 700.214 Right septum current : 724.498

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.18319 Left Arm Q1 power supply : 1115.29 Left Arm Q1 gauss meter : -0.09277 Left Arm Q2 gauss meter : 0.4706 Left Arm Q2 power supply current : 889.56 Left Arm Q2 momentum : 2.18277 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 741.916 Left Arm D1 momentum : 2.18296 Left Arm D1 NMR : 0.807728 Left Arm Q3 gauss meter : -0.53145 Left Arm Q3 power supply current : 1053.14 Left Arm Q3 momentum : 2.18278 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.73499 Right Arm Q1 power supply : 880.888 Right Arm Q1 gauss meter : -0.022117 Right Arm Q2 power supply current : 708.708 Right Arm Q2 momentum : 1.73463 Right Arm Q2 gauss meter : 0.3735 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 597.319 Right Arm D1 momentum : 1.73477 Right Arm D1 NMR : 0.643753 Right Arm Q3 power supply current : 835.635 Right Arm Q3 momentum : 1.73525 Right Arm Q3 gauss meter : 0.3705 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.8504 Wien BDL (Gcm) : -1757.2 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 128 Laser power Hall A : 0 Rotating waveplate : 3496 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 700.235 Right Septum Magnet Current : 724.498 -----