• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 09:11:01 on May 6, 2012

    Entry number 382626

    keyword=End_of_Run_5733
    ****************************
     Run Number: 5733
     End of Run Comment:
    Run_type=Production,target_type=NH3 top,comment_text=P0=2.0497 GeV/c, HWP1=IN
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=4   ps4=9   ps5=0   ps6=0   ps7=0   ps8=50   
    
    EVENTS   : 5655872      
    
    TIME     : 17.444 mins  
    
    DEAD TIME:  13.36%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/7009.2 Hz   T2:T2: 0.0/71.7 Hz   T3:T3:6173.2/24692.6 Hz   T4:T4:43.4/391.0 Hz   T5:T5: 0.0/31594.9 Hz   T6:T6: 0.0/32527.7 Hz   T7:T7: 0.0/103915.3 Hz   T8:T8:20.5/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/7336151  T2:T2:      0/75048    T3:T3:6461142/25844570  T4:T4:  45474/409272   T5:T5:      0/33068829  T6:T6:      0/34045180  T7:T7:      0/108763110  T8:T8:  21435/1071771  
    
    AVERAGE CURRENT
    BCM 1 : 0.0473 uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.32192 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 47.99          
    BCM d1 : 50.96          
    
    
    ****************************
    End-of-run EPICS data for Run Number 5733 at Sun May 6 09:10:56 EDT 2012
    
    

    Target Info

    Target number in beam : 1 Target encoder position : 49100 uWave Frequency (Ghz) : 140139 RF Frequency (Mhz) : 213 Magnetic Field (T) : 999 Magnet Current : 999 VPT 3He (K) : 1.04157 VPT 4He (K) : 1.06819 NMR Area : -48.0362 Polarization : 68.4479

    General Run Info

    Beam energy (MeV) : 2252.94 Beam Current : 0.000125827 Beam Current (Hall C) : 0 Left arm angle : -0.179 Left arm momentum : 2.04965 Right arm angle : 0.197 Right arm momentum : 1.5961 Left septum current : 652.96 Right septum current : 663.71

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.05 Left Arm Q1 power supply : 1047.25 Left Arm Q1 gauss meter : -0.08716 Left Arm Q2 gauss meter : 0.4419 Left Arm Q2 power supply current : 835.084 Left Arm Q2 momentum : 2.04911 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 693.435 Left Arm D1 momentum : 2.04965 Left Arm D1 NMR : 0.758432 Left Arm Q3 gauss meter : -0.49913 Left Arm Q3 power supply current : 988.995 Left Arm Q3 momentum : 2.04984 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.59593 Right Arm Q1 power supply : 810.285 Right Arm Q1 gauss meter : -0.020352 Right Arm Q2 power supply current : 652.027 Right Arm Q2 momentum : 1.5959 Right Arm Q2 gauss meter : 0.3435 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 547.867 Right Arm D1 momentum : 1.5961 Right Arm D1 NMR : 0.592294 Right Arm Q3 power supply current : 768.795 Right Arm Q3 momentum : 1.59645 Right Arm Q3 gauss meter : 0.3408 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.2008 Wien BDL (Gcm) : -1738.4 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 142 Laser power Hall A : 0 Rotating waveplate : 329 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 652.834 Right Septum Magnet Current : 663.726 -----