• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:48:41 on May 14, 2012

    Entry number 385011

    keyword=End_of_Run_6126
    ****************************
     Run Number: 6126
     End of Run Comment:
    Run_type=Other,target_type=C12_40,comment_text=check beam position
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=1   ps4=0   ps5=0   ps6=0   ps7=0   ps8=0   
    
    EVENTS   : 304951       
    
    TIME     : 1.469 mins  
    
    DEAD TIME:  17.24%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/1166.7 Hz   T2:T2: 0.0/19.3 Hz   T3:T3:4179.8/4179.8 Hz   T4:T4: 0.0/89.7 Hz   T5:T5: 0.0/21498.5 Hz   T6:T6: 0.0/11946.1 Hz   T7:T7: 0.0/103891.4 Hz   T8:T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/102863   T2:T2:      0/1706     T3:T3: 368515/368515   T4:T4:      0/7907     T5:T5:      0/1895440  T6:T6:      0/1053239  T7:T7:      0/9159691  T8:T8:      0/90282    
    
    AVERAGE CURRENT
    BCM 1 : 0.0546 uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -2.64802 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 4.67           
    BCM d1 : 4.962          
    
    
    ****************************
    End-of-run EPICS data for Run Number 6126 at Mon May 14 19:48:36 EDT 2012
    
    

    Target Info

    Target number in beam : 6 Target encoder position : 12339 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 0 Magnet Current : 121.819 VPT 3He (K) : 999 VPT 4He (K) : 0 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 3352.4 Beam Current : -0.0682407 Beam Current (Hall C) : 0 Left arm angle : 12.502 Left arm momentum : 2.82003 Right arm angle : 12.5005 Right arm momentum : 2.20167 Left septum current : 960.265 Right septum current : 939.096

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.81986 Left Arm Q1 power supply : 1440.54 Left Arm Q1 gauss meter : -0.11984 Left Arm Q2 gauss meter : 0.6074 Left Arm Q2 power supply current : 1149.19 Left Arm Q2 momentum : 2.81984 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 978.875 Left Arm D1 momentum : 2.82003 Left Arm D1 NMR : 1.04406 Left Arm Q3 gauss meter : -0.68601 Left Arm Q3 power supply current : 1360.55 Left Arm Q3 momentum : 2.81994 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 2.20182 Right Arm Q1 power supply : 1117.91 Right Arm Q1 gauss meter : -0.027912 Right Arm Q2 power supply current : 899.604 Right Arm Q2 momentum : 2.20186 Right Arm Q2 gauss meter : 0.4741 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 769.801 Right Arm D1 momentum : 2.20167 Right Arm D1 NMR : 0.817013 Right Arm Q3 power supply current : 1060.44 Right Arm Q3 momentum : 2.20208 Right Arm Q3 gauss meter : 0.47 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 12.5 Left Arm Angle Vernier : 31.4 Left Arm Scattering Angle : 12.502 ----- Right Arm Angle Floor Angle : 12.5 Right Arm Angle Vernier : -34.1 Right Arm Scattering Angle : 12.5005 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.2008 Wien BDL (Gcm) : -1738.4 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 182 Laser power Hall A : 0 Rotating waveplate : 329 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 959.95 Right Septum Magnet Current : 939.096 -----