• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name adaq

    Log entry time 14:58:26 on June 17, 2014

    Entry number 646

    keyword=Start_Run_1538,Run_type=Other,target_type=Home(no target, or empty),comment_text=Other
    Run Timestamp:       Tue Jun 17 14:58:07 EDT 2014
    Beginning-of-run EPICS data for Run Number 1538 at Tue Jun 17 14:58:09 EDT 2014
    

    Shift Worker Info

    Run_type=Other target_type=Home(no target, or empty) comment_text=Other

    Prescale Values

    ;This file is automatically generated from L-HRS prescales GUI. ;To generate this file, type "prescaleL" without quotes on adaq@adaq1 ;Input the desired prescales and Save. ;T1 = L-arm s0 && S2m trigger ;T2 = L-arm s0 && GC trigger ;T3 = L-arm s2 && GC trigger ;T4 = L-arm s0 && Shower trigger ;T5 = L-arm s2m && Shower trigger ;T6 = L-arm GC && Shower trigger ;T7 = L-arm EDTM trigger ;T8 = 103.7 KHz pulser ps1=1,ps2=1,ps3=1,ps4=1,ps5=1,ps6=1,ps7=100,ps8=1000

    General Run Info

    Misc Epics Info

    Left Arm Q1 momentum : HacL_Q1_P0rb --- Invalid channel name Left Arm Q1 power supply : 0.213626 Left Arm Q1 gauss meter : 0.0001892 Left Arm Q2 power supply current : -0.000467975 Left Arm Q2 momentum : -9.99853e-07 Left Arm Q2 gauss meter : 0.0009826 Left Arm Q2 power supply polarity : HacL_VMIC1182:0_Ch17 --- Invalid channel name Left Arm D1 power supply current : 0.0670319 Left Arm D1 momentum : 0.00257941 Left Arm D1 NMR : 9 Left Arm Q3 power supply current : -0.000342301 Left Arm Q3 momentum : -1.78573e-06 Left Arm Q3 gauss meter : -0.00014206 Left Arm Q3 power supply polarity : HacL_VMIC1182:0_Ch26 --- Invalid channel name Left Arm B Field Hall Probe (D-G) : -0.0009226

    Target Info

    ----- Target : Carbon fan frequency loop 1 : 0 fan frequency loop 2 : 0 Encoder position : 2.17977e-38 Target type : 2.17977e-38 temperature loop 1(1) : 5.889 temperature loop 1(2) : 5.889 temperature loop 1(3) : 5.889 Heat exchange loop 1 D2 : 5.889 temperature loop 2(1) : 5.721 temperature loop 2(2) : 5.782 temperature loop 2(3) : 5.721 Heat exchange loop 2 LH2 : 5.721 pressure loop He : 0 pressure loop H2 before : 14.1909 pressure loop H2 return : 14.5449 pressure loop D2 before : 13.9651 pressure loop D2 return : 13.55 HPH loop 1 : 2.23864 HPH loop 2 : 2.37355 HPH loop 3 : 2.40952

    Detector High Voltage

    S0 *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli S2m *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli Cerenkov *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli PRL1 *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli PRL2 *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli VDC *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli Straw Chamber *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli

    Detector High Voltage Current

    S0 *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli S2m *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli Cerenkov *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli PRL1 *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli PRL2 *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli VDC *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli Straw Chamber *** Error - the HV client program is missing /adaqfs/home/adev/slowc/hvg/hvcli