    User name R. Michaels

    Log entry time 22:28:45 on October 11,1998

    Entry number 2687

    This entry is a followup to: 2671

    keyword=waveplate at 120

    Moved have waveplate to 120, so another 24 CCWfrom
    previous setting.

    Note runs 8083 (HAPPEX) and 1707 (spectr) were done
    during waveplate change -- not useful.

    Runs 8084 (HAPPEX), 1708 (spectr), 4027 (Moller) at 120 units
    Charge asymmetries

    Spectrometer q1 -0.19%, q10 -0.22%
    HAPPEX 0.154 +/- 0.006 % (see note about SIGNS !!)
    Moller -0.12 +/- 0.02 %

    Note about signs: In the previous runs listed in this sequence,
    the Moller signs were always negative, but they didnt' tell me
    (its recorded correctly in Moller log book). So I finally record
    it correctly here. I have been recording consistently the same
    sign convention for HAPPEX and spectrometer DAQ, and in
    this run they became OPPOSITE SIGN (bad!!!). For Moller and
    HAPPEX DAQ, the relative sign has never changed.