    Entry number 38147

    keyword=Arc Energy (4 pass)

    The arc energy measurement for the 4 pass beam gives:

    3397.6 MeV +/- 0.6 Mev

    The data1234 scans in dispersive mode were recorded in files 820 and 821.
    Giving values of 34.3037 and 34.3030 degrees.
    The arc integral was recorded in files 666 thru 672. (6785.35 Tmm)