Main INDEX
Monthly INDEX
PREV
NEXT
User name S. Strauch
Log entry time 08:19:23 on April12,2000
Entry number 38978
keyword=Shift summary
Shift summary
----------
4He(e,e'p) runs @ Q2 = 1.0 GeV2, parallel to Compton measurements
00:30 raster check, trig-setup
00:45 asked MCC to increase the beam current to 40 uA
01:00 found FPP HV channel 7.1.4 tripped
02:30 second FPP HV channel 7.1.4 trip, checked gas flow, seems all right
1391 : 1.1 M events, FPP trip
1392 : 1.2 M events, FPP trip
1393 : 1.0 M events, FPP trip
1394 : 0.2 M events, FPP trip
1395 : 0.2 M events, FPP trip
1396 : 0.5 M events, FPP trip
total 4.2 M events, but with FPP trip in at least a fraction of the runs
03:00 FPP up again
03:55 asked MCC to correct the beam position
1397 : 1.1 M events, FPP OK
1398 : 1.2 M events, FPP OK
1399 : 0.3 M events, FPP OK, beam pos. off by 0.3 mm
1400 : 1.2 M events, FPP OK
1401 : 1.2 M events, FPP OK
1402 : 1.2 M events, FPP OK
1403 : 1.2 M events, FPP OK
1404 : 1.2 M events, FPP OK
1404 : 1.2 M events, FPP OK
1405 : 1.2 M events, FPP OK
1406 : 1.2 M events, FPP OK
1407 : 1.2 M events, FPP OK
total 13.4 M events / 5 h on average 2.68 M events/h
smooth data taking between 03:00 and 08:00