Main INDEX
Monthly INDEX
PREV
NEXT
User name M Jones
Log entry time 05:58:15 on May10,2000
Entry number 40873
keyword=scan of adc gate
scan of adc gate. After the width of the ADC gate was changed to 100ns
the delay of the hadron arm was varied to find the maximum in the
adc value for the lead glass. Measured the peak position of the
adc in two blocks. For delay three channels were used and
each bit in the channels 8ns
Run gate width delay adc peak block 22 adc peak block 24
--- ------ ---- ------------ ------------
2166 200 14,11,12 1798 1754
2173 100 14,11,12 1436 1449
2174 100 14,15,12 1242 1000
2175 100 14,7,12 1210 1242
2176 100 14,9,12 1303 1371
2177 100 14,10,12 1342 1397
2178 100 14,12,12 1470 1363
2179 100 14 ,13,12 1428 1277
Decide that delay of 14,11,12 was best for both blocks.