User name R. Michaels
Log entry time 01:14:03 on May12,2000
Entry number 41069
This entry is a followup to: 41037
keyword=current ramp-up continued
After about 1.25 hours of access to raise trip level, we
can continue the ramp up of current on lead target.
run....time......current.......temp........rate
.........min.........muA.........K(/10)......kHz
2253....0..........5.1............132..........11.9
2254....5..........20.4...........196.........51.8
EPICS/medm reading of BPMs 4A,4B stop
working. But the CODA data looks ok.
2256....10.........25.............252...........62.7
2257.....15........30.............281...........73.7
2258.....17........35.............313...........87
2259.....19.........40............327...........91
2260......24.........45............356..........104
2262......30.........50............................110
Will leave it at 50 microamps for about an hour.
.............45..........50..........403...........108
2263.....53..........50..........417...........105
Noticed beam drifted to (-0.2, 0). Asked MCC
to fix this to (0,0). After this
2265.....63.........50...........417...........95
The beam position is very unstable. It dances
around by 200 microns on the EPICS screen.
Fast feedback is not working.
...........80...........50...........413.........95
...........82....notice Q1E tripped off.
We cannot reset it. Test is finished.
Mark Stevens is coming in anyway. He can fix it.
Note that T2 ~ 0.9 T1. Lots of junk.