User name R Roche
Log entry time 08:02:16 on May31,2000
Entry number 42458
Followups:
keyword=shift summary
Continue thcm=90, ph=0 production
.
..run....start time....events
1503.......24:56.......1256 k
1504.......00:13.......1253 k
1505.......00:33.......1250 k
1506.......00:52.......1250 k
1507.......01:09.......1211 k
.
01:28 MCC zone problem. Ended run 1507.
.
1508.......01:31.......1250 k
1509.......01:49.......1250 k
1510.......02:08.......1250 k
1511.......02:28.......1250 k
.
1512......JUNK
1513......JUNK
.
Beginning of Run 1512 (02:49) it was noticed that the electron arm VDC HVs read 0. Meekins' attempted to reboot by pushing the green "electron arm VDC HV" buttons in the middle room. Didn't work. Attempted to fix the problem through the vax terminal. Maybe it worked.
.
03:09 beginning Run 1514 to check electron wire maps. No electron signals.
.
1514.......JUNK
.
03:32 Can't fix problem from here. Asked for access to reset these HVs.
.
04:20 Problem still not fixed. Calling Bogdan for help. His suggestion:
...............Set E_top and E_btm VDC HVs to 0
...............The readings turned green
...............Push green "electron arm VDC HV" buttons for 10 sec, simultaneously
...............Try setting one of the E_top or E_btm VDC HVs to 0.500
...............Still didn't work.
...............Try it all again.
...............Didn't work again.
04:33 Dave is going into the hall again and calling Bogdan from there.
05:01 No help. Bogdan is coming in.
05:31 Bogdan can't fix it. Determined the VME controlling HV and threshold on VDC in Earm is not working. Now time to call Javier (who is out of town). Paged Jack Segal.
.
Bogdan and Dave made a local control for HV and threshold.
.
06:34 Beginning Run 1515 with all prescales set to 1.
Run 1515 failed. No connection to ROC 14.
Reboot CODA
.
06:42 Beginning Run 1516 with all prescales set to 1. Looks good. Asked MCC to close the hall.
.
Runs 1515 - 1517 JUNK
.
07:20 Beam back. Begin Run 1518 (12C target) run to check raster. Prescales were too high to see spot. Begin Run 1519 to check raster. Looks fine. Switching to H2 target.
.
run.......start........events
1520....07:31.......1250 k
1521....07:50.......