    User name Z. Chai

    Log entry time 19:59:19 on June 3,2000

    Entry number 42989

    keyword=Increase current to 50 uA for (155,0) kin.

    Run 1723, I_beam=25uA, 1st picture
    The fisrt plot is tc_cor without any cuts. The second plot is tc_cor with the proton and vertex difference cut abs(e.reactz-h.reactz)<0.03. The third plot is the tc_cor with the same cuts of the second plus the missing mass cut 100 The resulted Signal to Noise ratio is 7:1 ( For the Beam current 25 uA)

    Adam decided we should increase the current to 50 uA to get more interested
    coincidence events.

    Run 1733, I_beam = 50uA, second picture
    with the same proton , vertex and missing mass cuts,
    the Signal to Noise ratio is 4:1.

    It seems we can just keep taking data at this high current.





    FIGURE 1

    FIGURE 2