    User name Calarco

    Log entry time 11:18:00 on June 4,2000

    Entry number 43079

    keyword=Energy Fluctuation

    The red trace in the attached strip chart shows the x-position at monitor ph1c12
    which is in the dispersive section of the arc. The dispersion is 4 m per fractional
    change in energy, i.e. a 4 mm change in x corresponds to a change in beam energy
    of 1 part in 1000. There has been a slow rise from about -0.4 mm (which is now
    off the time scale) up to about +0.3 mm, with a sharp negative excursion of 2 mm
    which seems to have been triggered by a loss of beam current and which was
    recovered after about 5 minutes.


    FIGURE 1