Main INDEX
Monthly INDEX
PREV
NEXT
User name Ole Hansen
Log entry time 07:58:12 on June11,2000
Entry number 43456
keyword=Shift Summary
At start of shift, work in progress in the Hall to replace broken cooling water pump for the beam diffuser.
~1:00 .. Q3 on electron arm quenches. Mark Stevens resets it while in the Hall.
1:50 ... Pump fixed. Water flow restored. Ready for beam.
2:00 ... Beam arrives. Quick spot check.
2:20 ... Start production. Current ~60uA.
2:30 ... High deadtime. Resetting CODA.
2:33 ... Start run #1919. Deadtime looks better (~19%).
2:50 ... Bad beam, RF trips every 10 minutes.
3:55 ... Beam was nice and stable for a while during run 1922, trips now during 1923.
4:20 ... Intermittent beam again, run# 1924. Beam current 60uA as before.
5:45 ... Target IOC crash. We're down for a few minutes.
6:00 ... IOC is back. Resume data taking.
6:05 ... Beam is back, but trips a lot.
6:08 ... Stable beam now.
6:40 ... Ending run 1931 early because the deadtime is fluctuating again. Resetting CODA.
7:07 ... Another Q3 quench. Asking for access...
7:45 ... Q3 OK. Resuming production.
Start time ... Run# ... #Events ... Comments
07:45 .......... 1934 ..... 1.3M
07:01 .......... 1933 ..... n/a ............ Ended because of Q3 quench
06:41 .......... 1932 ..... 1.3M
06:19 .......... 1931 ..... 1.2M ........ Deadtime fluctuations, ended early
06:01 .......... 1930 ..... 1.3M
05:38 .......... 1929 ..... 0.7M ........ Ended because of target IOC crash
05:21 .......... 1928 ..... 1.3M
05:03 .......... 1927 ..... 1.3M
04:46 .......... 1926 ..... 1.3M
04:29 .......... 1925 ..... 1.3M
04:08 .......... 1924 ..... 1.3M ........ More beam trips
03:49 .......... 1923 ..... 1.3M ........ Frequent beam trips
03:31 .......... 1922 ..... 1.3M
03:13 .......... 1921 ..... 1.3M
02:52 .......... 1920 ..... 1.3M ........ Frequent beam trips
02:33 .......... 1919 ..... 1.3M
02:15 ...........1918 ........................ High deadtime, bad run