    User name M Jones

    Log entry time 12:53:37 on June27,2000

    Entry number 44995

    keyword=gas problems

    gas problems.
    Noticed sudden change in VDC efficiency. see figures below
    Checked gas mixture in gas shed. Jack has setup a straw tube in the
    gas shed so that one can look at the signal from a 55Fe source
    and flush gas through quickly.
    First he looked at the signal with present gas mixture.
    Then he changed both gas bottles and again looked at the signal
    There was a marked difference in the signal.
    Then he connected a bottle of premix and looked at the signal.
    This signal looked like the signal with the new gas bottles. Change at 12:30pm
    So we decided to keep running with the new bottles
    and see if the efficiency improves.


    FIGURE 1

    FIGURE 2