• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name M JOnes

    Log entry time 08:24:28 on July 8,2000

    Entry number 45353

    keyword=summary of owl shift


    Summary of owl shift
    ---------------
    12:00 no beam. Estimate beam at 1:00
    12:30 Problem with TS0 during cosmic run. Had to reboot TS0.
    Problem with reboot see separate halog entry.
    1:30 Arun is at MCC. Turn on HV channels 1.0 and 1.1 to 1200V on hac42
    Try to reboot arcioc but remote reboot by pushing green button doesn't
    seem to work.
    1:50 Hadron dipole quenches helium level 2%. Level on Q1 56%
    ESR temperature is dropping
    1:55 Hadron Q1 quenches
    Electron Q1 and dipole quench
    2:50 All magnets have helium levels back to normal. All magnets
    reset ok. Trouble setting hadron dipole.
    3:00 Problem moving Compton electron detector out of beam.
    tell MCC that they must use Compton chicane until access
    to try and fix problem.
    4:50