User name adev
Log entry time 09:19:02 on November 6, 2000
Entry number 51584
keyword=Start_Run_1118_Tar=LH2-15cm,Type=Elastic,Lmom=2.6417,Rmom=2.735,Ene=4.607,Angle_R=30.593,Angle_L=31.755
Beginning-of-run EPICS data for Run Number 1118 at Mon Nov 6 09:18:47 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10,ps3=1,ps4=2000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 2056.6
Right Arm Q1 momentum : 2.73508
Right Arm Q1 gauss meter : -0.05133
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1176.86
Right Arm Q2 momentum : 2.73454
Right Arm Q2 gauss meter : 0.6183
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 972.546
Right Arm D1 momentum : 2.735
Right Arm D1 NMR : 1.01493
Right Arm Q3 power supply current : 1088.25
Right Arm Q3 momentum : 2.73493
Right Arm Q3 gauss meter : 0.488
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1987.33
Left Arm Q1 momentum : 2.64157
Left Arm Q1 gauss meter : 0.16879
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1137.45
Left Arm Q2 momentum : 2.64155
Left Arm Q2 gauss meter : -0.5993
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 914.774
Left Arm D1 momentum : 2.6417
Left Arm D1 NMR : 0.977889
Left Arm Q3 power supply current : 1051.7
Left Arm Q3 momentum : 2.64167
Left Arm Q3 gauss meter : 0.5249
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 46.9421
Current on Unser monitor : 48.465
Current on Upstream bcm : 47.2542
Current on Downstream bcm : 46.6301
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 70.5463
Beam energy : 4615.33
MBSY1c magnet current (amp) : 192.523
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.23
haSC200_6_Sensor_2_R : 26.22
haSC200_6_Sensor_3_R : 3.39
haSC200_6_Sensor_4_R : 38.78
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 118.8
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 54.7
haITC502_5_Sensor_1_R : 74.26
haITC502_5_Sensor_2_R : 66.94
haITC502_5_Sensor_3_R : 138.8
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.2
Right Arm Arm Collimator : 0.86543
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1192
HacR_VPM_LVDT:VALr : -140
HacR_HPE1313A:0_Ch58 : -0.538574
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.753906
HacR_alignROLL : -0.272287
HacR_alignPITCH : -0.0176089
HacR_alignHPT : -1.51617
HacL_HPM_LVDT:VALr :
HacL_VPM_LVDT:VALr : 669
HacL_HPE1313A:0_Ch58 : -0.171387
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.243164
HacL_alignROLL : 0.117984
HacL_alignPITCH : -0.0919198
HacL_alignHPT : 4.97089
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : -20
Right Arm Scattering Angle : 30.592
Left Arm Angle Floor Angle : 32
Left Arm Angle Vernier : -5.6
Left Arm Scattering Angle : 31.7551
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -573.44
Wien field : 16.703
Laser attenuation Hall A : 232
Laser power Hall A : 100
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88