User name adev
Log entry time 17:54:50 on November 6, 2000
Entry number 51607
keyword=Start_Run_1125_Tar=LH2-15cm,Type=Elastic,Lmom=2.6417,Rmom=2.735,Ene=4.607,Angle_R=30.593,Angle_L=31.755
Beginning-of-run EPICS data for Run Number 1125 at Mon Nov 6 17:54:33 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=1,ps2=10,ps3=1,ps4=2000,ps5=1,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 2056.64
Right Arm Q1 momentum : 2.73512
Right Arm Q1 gauss meter : -0.05133
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1177.22
Right Arm Q2 momentum : 2.73538
Right Arm Q2 gauss meter : 0.6183
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 972.551
Right Arm D1 momentum : 2.735
Right Arm D1 NMR :
Right Arm Q3 power supply current : 1088.25
Right Arm Q3 momentum : 2.73493
Right Arm Q3 gauss meter : 0.488
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 1987.37
Left Arm Q1 momentum : 2.64161
Left Arm Q1 gauss meter : 0.16878
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1137.42
Left Arm Q2 momentum : 2.64148
Left Arm Q2 gauss meter : -0.5992
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 914.76
Left Arm D1 momentum : 2.64169
Left Arm D1 NMR : 0.977885
Left Arm Q3 power supply current : 1051.73
Left Arm Q3 momentum : 2.64175
Left Arm Q3 gauss meter : 0.5249
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 66.8377
Current on Unser monitor : 68.2914
Current on Upstream bcm : 66.8679
Current on Downstream bcm : 66.8075
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 101.784
Beam energy : 4615.33
MBSY1c magnet current (amp) : 192.523
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.91
haSC200_6_Sensor_2_R : 26.18
haSC200_6_Sensor_3_R : 3.56
haSC200_6_Sensor_4_R : 38.9
haHe_Omega_DPG_Sensor_R : -0.027
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 118.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 55
haITC502_5_Sensor_1_R : 75.22
haITC502_5_Sensor_2_R : 67.69
haITC502_5_Sensor_3_R : 138.4
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.21
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868604
HacR_HPM_LVDT:VALr : -1220
HacR_VPM_LVDT:VALr : -197
HacR_HPE1313A:0_Ch58 : -0.535645
HacR_HPE1313A:0_Ch55 : 22.6074
HacR_HPE1313A:0_Ch54 : -0.751465
HacR_alignROLL : -0.271122
HacR_alignPITCH : -0.0191548
HacR_alignHPT : -1.48661
HacL_HPM_LVDT:VALr : 1.04069e+06
HacL_VPM_LVDT:VALr : 604
HacL_HPE1313A:0_Ch58 : -0.168457
HacL_HPE1313A:0_Ch55 : 24.1211
HacL_HPE1313A:0_Ch54 : -0.243652
HacL_alignROLL : 0.118041
HacL_alignPITCH : -0.0950552
HacL_alignHPT : 4.97089
Right Arm Angle Floor Angle : 30.5
Right Arm Angle Vernier : -20
Right Arm Scattering Angle : 30.5918
Left Arm Angle Floor Angle : 32
Left Arm Angle Vernier : -5.6
Left Arm Scattering Angle : 31.7551
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -772.93
Wien field : 22.498
Laser attenuation Hall A : 340
Laser power Hall A : 100
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88