• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Higinbotham

    Log entry time 06:50:48 on November 7,2000

    Entry number 51642

    Followups:

    keyword=Problems . . .

    At 4:55 the machine went down due to RF problems.

    At 5:30 we notice that the last two flitered files (1136,1137) contain no data, but
    when we look at the data using ESPACE everything looks fine.


    In trying to find what is going wrong, we find that we cannot connect to the FPP
    portserver to check the HVs. We are able to connect to the other ports. Mark Jones
    new software indicates that the HV are OK. Stopping Mark's program doesn't seem
    to help.

    We also find that we cannot telent to ROC1?! This is the fastbus in the right arm.
    We restart CODA and it still is running and if we ping ROC1, it is alive.