    User name adev

    Log entry time 07:09:29 on November 7, 2000

    Entry number 51644

    keyword=End_of_Run_1140
    ****************************
     Run Number: 1140
    End of Run Comment:
    Tar=LH2-15cm,Type=Cosmic,Lmom=2.6417,Rmom=2.735,Ene=4.607,Angle_R=30.593,Angle_L=31.755
    junk
    
    
    Time of run = 26.415088 min
    Av. current (on 3x) = 2.1201267 uA
    Av. current (on 1x) = 2.1087064 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    3.3421  |    3.3602  |    3.3941
    up-down    (mC)|    0.2036  |    0.0578  |    0.1081
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |      4796.4 /mC  |   10.169 Hz  |     16117  |     1   |      4822.4 /mC
        2      |         0.0 /mC  |    0.000 Hz  |         0  |    10   |         0.0 /mC
        3      |     15886.6 /mC  |   33.682 Hz  |     53382  |     1   |     15972.6 /mC
        4      |   1098329.0 /mC  |    1.164 Hz  |   3690605  |  2000   |   1104277.3 /mC
        5      |      4795.5 /mC  |   10.167 Hz  |     16114  |     1   |      4821.5 /mC
        output                        34.266 Hz
    Av. deadtime from accepted triggers = 0.0167
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  10.237549  Hz     |    10.085149 Hz   |  10.169062 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        3      |  33.523156  Hz     |    33.729476 Hz   |  33.681508 Hz
        4      |  2328.2582  Hz     |    2329.5048 Hz   |  2328.5965 Hz
        5      |  10.23372  Hz     |    10.085149 Hz   |  10.167169 Hz
        output |  0.0  Hz   |    0.0 Hz |    34.266 Hz
    Accepted triggers  =  54308.00000
     Time of run = 26.415088 min
     Time of run h- = 13.058805 min
     Time of run h+ = 13.058138 min
     1-(sum of time hel + and -)/( run time) = 1.1287e-02
    Rate of Left Arm Pulser for electronic DT  = 10.169062
    Rate of Right Arm Pulser for electronic DT  = 5.0608702
    Rate of Left Arm Pulser&trig for electronic DT  = 10.167169
    Rate of Right Arm Pulser&trig for electronic DT  = 5.0608702
    Left Arm Electronic DT  = 0.00018613886
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 4272.9846
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.236634  Hz         |    0.0 Hz        |  11.236634 Hz
          -        |  0.0  Hz        |    11.236003 Hz       |  11.236634 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0017009         |   0.0017026         | 0.0034439     
       upstream 3x |   0.0016736         |   0.0016753         | 0.0033891     
       upstream 10x|   0.0017027         |   0.0017045         | 0.0034481     
      downstream   |   0.0016001         |   0.0016019         | 0.0032403    
     downstream 3x |   0.0016451         |   0.0016467         | 0.0033313    
     downstream 10x|   0.0016493         |   0.0016511         | 0.0033400    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   4.99485820e-04 
       upstream 3x |   5.07629370e-04 
       upstream 10x|   5.28293030e-04 
      downstream   |   5.62148660e-04 
     downstream 3x |   4.86056260e-04 
     downstream 10x|   5.45388440e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1140 at Tue Nov  7 07:00:55 EST 2000
    Right Arm D1 momentum                    : 2.735
    Right Arm arm angle                      : 30.5918
    Left Arm D1 momentum                      : 2.64169
    Left Arm arm angle                        : 31.7551
    Tiefenbach Hall A energy                : 4602.19
    Right Arm arm mispointing (HPT)          : -1.4941
    Left Arm arm mispointing (HPT)            : 4.97089
    Right Arm Q1 power supply current        : 2056.6
    Right Arm Q1 momentum                    : 2.73508
    Right Arm Q1 gauss meter                 : -0.05133
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1176.9
    Right Arm Q2 momentum                    : 2.73464
    Right Arm Q2 gauss meter                 : 0.6183
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 972.55
    Right Arm D1 momentum                    : 2.735
    Right Arm D1 NMR                         : 1.01493
    Right Arm Q3 power supply current        : 1088.26
    Right Arm Q3 momentum                    : 2.73495
    Right Arm Q3 gauss meter                 : 0.488
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1987.37
    Left Arm Q1 momentum                      : 2.64161
    Left Arm Q1 gauss meter                   : 0.16877
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1137.65
    Left Arm Q2 momentum                      : 2.64201
    Left Arm Q2 gauss meter                   : -0.5993
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 914.769
    Left Arm D1 momentum                      : 2.6417
    Left Arm D1 NMR                           : 0.977886
    Left Arm Q3 power supply current          : 1051.77
    Left Arm Q3 momentum                      : 2.64184
    Left Arm Q3 gauss meter                   : 0.5249
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 46.5753
    Current on Unser monitor                : 48.2923
    Current on Upstream bcm                 : 46.4812
    Current on Downstream bcm               : 46.4024
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 69.596
    MBSY1c Hall A Beam energy               : 4615.33
    MBSY1c magnet current (amp)             : 192.523
    MBSY1c Bdl                              : 1.15176e+06
    MBSY3c Hall C Beam energy               : 2341.14
    Tiefenbach Hall A energy                : 4602.19
    Tiefenbach Hall C energy                : 2333.1
    Delta(E)/E width (MV_AI_DXWID)          : 0.101777
    IPM1C12.XPOS                            : -0.246771
    IPM1H04A.XPOS                           : 0.0328427
    IPM1H04A.YPOS                           : 0.649622
    IPM1H04B.XPOS                           : -0.0454615
    IPM1H04B.YPOS                           : -0.046173
    Right Arm Arm Collimator                 : 0.86543
    Left Arm Arm Collimator                   : 0.868701
     HacR_HPM_LVDT:VALr                     : -1213
     HacR_VPM_LVDT:VALr                     : -150
     HacR_HPE1313A:0_Ch58                   : -0.537598
     HacR_HPE1313A:0_Ch55                   : 22.4609
     HacR_HPE1313A:0_Ch54                   : -0.753418
     HacR_alignROLL                         : -0.272108
     HacR_alignPITCH                        : -0.0178082
     HacR_alignHPT                          : -1.49388
     HacL_HPM_LVDT:VALr                     : 1.04069e+06
     HacL_VPM_LVDT:VALr                     : 672
     HacL_HPE1313A:0_Ch58                   : -0.169922
     HacL_HPE1313A:0_Ch55                   : 23.9258
     HacL_HPE1313A:0_Ch54                   : -0.244629
     HacL_alignROLL                         : 0.11636
     HacL_alignPITCH                        : 0
     HacL_alignHPT                          : 4.97089
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.59
    haH2_P_Exhaust_R                         : 22.41
    haH2_P_Fill_Bottle_R                     : 22.98
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.446
    haSC200_6_Sensor_1_R                     : 242.61
    haSC200_6_Sensor_2_R                     : 25.46
    haSC200_6_Sensor_3_R                     : 3.47
    haSC200_6_Sensor_4_R                     : 38.86
    haHe_Omega_DPG_Sensor_R                  : -0.028
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19.03
    haITC502_2_Sensor_2_R                    : 19.03
    haITC502_2_Sensor_3_R                    : 19.22
    haITC502_4_Sensor_1_R                    : 112.9
    haITC502_4_Sensor_2_R                    : 19.2
    haITC502_4_Sensor_3_R                    : 55.1
    haITC502_5_Sensor_1_R                    : 74.23
    haITC502_5_Sensor_2_R                    : 66.83
    haITC502_5_Sensor_3_R                    : 137.3
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 25.16
    Right Arm Arm Collimator                 : 0.86543
    Left Arm Arm Collimator                   : 0.868604
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -772.93
    Wien field                               : 22.498
    Laser attenuation Hall A                 : 320
    Laser power  Hall A                      : 100