User name adev
Log entry time 20:54:14 on November 9, 2000
Entry number 51773
keyword=Start_Run_1186_Tar=LH2-15cm,Type=Elastic,Lmom=2.9229,Rmom=2.468,Ene=4.607,Angle_R=34.53,Angle_L=28.598
Beginning-of-run EPICS data for Run Number 1186 at Thu Nov 9 20:54:03 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=65535,ps5=65535,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 2056.74
Right Arm Q1 momentum : 2.73526
Right Arm Q1 gauss meter : -0.05134
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1177.05
Right Arm Q2 momentum : 2.73499
Right Arm Q2 gauss meter : 0.6183
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 972.577
Right Arm D1 momentum : 2.735
Right Arm D1 NMR : 1.01493
Right Arm Q3 power supply current : 1088.15
Right Arm Q3 momentum : 2.73466
Right Arm Q3 gauss meter : 0.4881
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2199.08
Left Arm Q1 momentum : 2.92307
Left Arm Q1 gauss meter : 0.18667
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1258.61
Left Arm Q2 momentum : 2.92292
Left Arm Q2 gauss meter : -0.6629
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1021.27
Left Arm D1 momentum : 2.92289
Left Arm D1 NMR : 1.08223
Left Arm Q3 power supply current : 1163.74
Left Arm Q3 momentum : 2.9231
Left Arm Q3 gauss meter : 0.5808
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0373952
Current on Unser monitor : 0.5573
Current on Upstream bcm : 0.0396254
Current on Downstream bcm : 0.035165
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4615.32
MBSY1c magnet current (amp) : 192.523
haBDSPOS : 5.35401e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.86
haSC200_6_Sensor_2_R : 26.04
haSC200_6_Sensor_3_R : 3.46
haSC200_6_Sensor_4_R : 39.28
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 118.2
haITC502_4_Sensor_2_R : 18.8
haITC502_4_Sensor_3_R : 55.2
haITC502_5_Sensor_1_R : 75.87
haITC502_5_Sensor_2_R : 68.34
haITC502_5_Sensor_3_R : 138.6
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.1
Right Arm Arm Collimator : 0.865479
Left Arm Arm Collimator : 0.868652
HacR_HPM_LVDT:VALr : -1568
HacR_VPM_LVDT:VALr : -1565
HacR_HPE1313A:0_Ch58 : -0.569824
HacR_HPE1313A:0_Ch55 : 22.5586
HacR_HPE1313A:0_Ch54 : -0.868164
HacR_alignROLL : -0.387516
HacR_alignPITCH : 0.0123314
HacR_alignHPT : -0.955641
HacL_HPM_LVDT:VALr : -7726
HacL_VPM_LVDT:VALr : 577
HacL_HPE1313A:0_Ch58 : -0.164062
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.239746
HacL_alignROLL : 0.121291
HacL_alignPITCH : -0.0982543
HacL_alignHPT : 4.85416
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5075
Left Arm Angle Floor Angle : 29
Left Arm Angle Vernier : -38
Left Arm Scattering Angle : 28.5691
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -772.93
Wien field : 22.498
Laser attenuation Hall A : 200
Laser power Hall A : 100
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88