User name adev
Log entry time 13:45:38 on November 10, 2000
Entry number 51820
keyword=Start_Run_1184_Tar=LH2-15cm,Type=Elastic,Lmom=2.9229,Rmom=2.468,Ene=4.607,Angle_R=34.53,Angle_L=28.598
Beginning-of-run EPICS data for Run Number 1184 at Thu Nov 9 20:39:40 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=65535,ps5=65535,ps6=65535,ps8=65535
Right Arm Q1 power supply current : 2056.6
Right Arm Q1 momentum : 2.73508
Right Arm Q1 gauss meter : -0.05134
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 1176.84
Right Arm Q2 momentum : 2.7345
Right Arm Q2 gauss meter : 0.6183
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 972.565
Right Arm D1 momentum : 2.735
Right Arm D1 NMR : 1.01493
Right Arm Q3 power supply current : 1088.23
Right Arm Q3 momentum : 2.73488
Right Arm Q3 gauss meter : 0.4881
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2199.12
Left Arm Q1 momentum : 2.92307
Left Arm Q1 gauss meter : 0.18667
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1258.46
Left Arm Q2 momentum : 2.92258
Left Arm Q2 gauss meter : -0.6629
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1021.27
Left Arm D1 momentum : 2.92289
Left Arm D1 NMR : 1.08223
Left Arm Q3 power supply current : 1163.77
Left Arm Q3 momentum : 2.92316
Left Arm Q3 gauss meter : 0.5808
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 3.27917
Current on Unser monitor : 6.84595
Current on Upstream bcm : 0.0384988
Current on Downstream bcm : 6.51983
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 11.0834
Beam energy : 4615.32
MBSY1c magnet current (amp) : 192.523
haBDSPOS : 5.35401e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.85
haSC200_6_Sensor_2_R : 26.08
haSC200_6_Sensor_3_R : 3.56
haSC200_6_Sensor_4_R : 39.35
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 118.4
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 55
haITC502_5_Sensor_1_R : 75.57
haITC502_5_Sensor_2_R : 68.01
haITC502_5_Sensor_3_R : 137.3
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 25.06
Right Arm Arm Collimator : 0.865527
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1582
HacR_VPM_LVDT:VALr : -1595
HacR_HPE1313A:0_Ch58 : -0.571289
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -0.870605
HacR_alignROLL : -0.390038
HacR_alignPITCH : 0.0122
HacR_alignHPT : -0.917578
HacL_HPM_LVDT:VALr : -7721
HacL_VPM_LVDT:VALr : 567
HacL_HPE1313A:0_Ch58 : -0.164551
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.240234
HacL_alignROLL : 0.119894
HacL_alignPITCH : -0.0982543
HacL_alignHPT : 4.84495
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5074
Left Arm Angle Floor Angle : 29
Left Arm Angle Vernier : -38
Left Arm Scattering Angle : 28.5693
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -772.93
Wien field : 22.498
Laser attenuation Hall A : 205
Laser power Hall A : 100
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88