User name Huber
Log entry time 15:55:05 on November12,2000
Entry number 51945
keyword=Day shift summary
08:05-08:25 Beam off for gp>pi0p test. Test aborted due to problems with radiator control at MCC. See Ron's entry 51927.
08:30 Start controlled access.
Left HRS: Q2,Q3 cycled to 1600A and momentum set to 3.8086 GeV/c.
Changed FPP chamber 4 HV from channel 8.1.8 to 8.1.16.
Bogdan made some adjustments to the S1,S2 set HV.
Test with cosmics run 1245. All OK.
Left HRS moved to 19.345 degrees - floor mark 19.5 reads vernier +9.7. This differs from the desired 19.376 by about 0.03 degrees.
Calorimeter now at 9m+/-1cm and 51.44+/-0.02 degrees.
Now set up for Q2=5.6.
Carbon foil target now in.
Run 1247 - Carbon pointing run.
Run 1248 - HARP scan - data file # 1166.
Survey offsets: X(5)=-0.07 Y(5)= 0.08 X(6)=-0.45 Y(6)=-0.23 mm
***************************************************************
Uncorrected Corrected Sigma
Base
position position Width Width
Scanner #5 4ax: 42.0um -28.0um 89.0um
Scanner #5 4ay: 863.00um 943.00um 22.2um
Scanner #6 4bx: 460.00um 10.00um 94.0um
Scanner #6 4by: 581.00um 351.00um 10.2um
***************************************************************
Uncorrected Corrected
position position
Target x pos : 535.27 um 16.84 um (+ for beam left)
Target y pos : 530.22 um 244.40 um (+ for too high)
Beam h angle: -0.07 mrad -0.01 mrad (+ for clockwise)
Beam v slope: -0.05 mrad -0.10 mrad (+ for ascending slope)
***************************************************************
Done
11:25-12:20 Calorimeter ADCs present but TDCs absent. Re-enter hall to
reconnect power cord to calorimeter discriminator crate.
15:00 Jack replaced the gas shed Argon bottle. We had received a low pressure alarm.
Run Start Stop Events Comments
1249 12:20 13:15 1M First Q2=5.6 run.
1250 13:16 14:11 1M
1251 14:11 15:10 1M
1252 15:11