User name adev
Log entry time 19:31:09 on December 1, 2000
Entry number 52658
keyword=Start_Run_1543_Tar=carbon,Type=Other,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1543 at Fri Dec 1 19:30:59 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.77e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.120702
Right Arm Q2 momentum : 0.000280463
Right Arm Q2 gauss meter : 0.0005548
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97484
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.22471
Right Arm Q3 power supply current : 0.220167
Right Arm Q3 momentum : 0.00055331
Right Arm Q3 gauss meter : 0.000258
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24303
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.89
Left Arm Q2 momentum : 3.80838
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.29
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.38
Left Arm Q3 momentum : 3.80887
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.5181
Current on Unser monitor : 25.8472
Current on Upstream bcm : 30.0063
Current on Downstream bcm : 29.0298
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 34.33
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.08181
Radiator Encoder : 0.151404
haBDSPOS : 732010
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.45
haSC200_6_Sensor_2_R : 19.01
haSC200_6_Sensor_3_R : 3.17
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 84.3
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 68.8
haITC502_5_Sensor_1_R : 62.78
haITC502_5_Sensor_2_R : 61.91
haITC502_5_Sensor_3_R : 202.4
haITC502_6_Sensor_1_R : 97.94
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.75
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868799
HacR_HPM_LVDT:VALr : -1331
HacR_VPM_LVDT:VALr : -1746
HacR_HPE1313A:0_Ch58 : -0.564941
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.83252
HacR_alignROLL : -0.351794
HacR_alignPITCH : 0.0066818
HacR_alignHPT : -1.24241
HacL_HPM_LVDT:VALr : -7480
HacL_VPM_LVDT:VALr : 1770
HacL_HPE1313A:0_Ch58 : -0.117188
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.155762
HacL_alignROLL : 0.194848
HacL_alignPITCH : -0.140677
HacL_alignHPT : 4.53128
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5094
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2603
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 175
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88