User name adev
Log entry time 19:37:09 on December 1, 2000
Entry number 52659
keyword=Start_Run_1544_Tar=carbon,Type=Other,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1544 at Fri Dec 1 19:37:00 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.43e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.290628
Right Arm Q2 momentum : 0.000675302
Right Arm Q2 gauss meter : 0.0005577
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97482
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.66501
Right Arm Q3 power supply current : 0.0636153
Right Arm Q3 momentum : 0.000159874
Right Arm Q3 gauss meter : 0.0002536
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.59
Left Arm Q1 momentum : 3.80895
Left Arm Q1 gauss meter : 0.24303
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.99
Left Arm Q2 momentum : 3.80862
Left Arm Q2 gauss meter : -0.8626
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.29
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.25
Left Arm Q3 momentum : 3.80854
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.4087
Current on Unser monitor : 26.2224
Current on Upstream bcm : 28.4794
Current on Downstream bcm : 28.338
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 33.6182
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.156288
haBDSPOS : 732010
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.5
haSC200_6_Sensor_2_R : 18.91
haSC200_6_Sensor_3_R : 3.19
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 84.1
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 68.7
haITC502_5_Sensor_1_R : 62.76
haITC502_5_Sensor_2_R : 61.94
haITC502_5_Sensor_3_R : 202
haITC502_6_Sensor_1_R : 97.92
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.73
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1330
HacR_VPM_LVDT:VALr : -1746
HacR_HPE1313A:0_Ch58 : -0.564453
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.832031
HacR_alignROLL : -0.351358
HacR_alignPITCH : 0.00674766
HacR_alignHPT : -1.24154
HacL_HPM_LVDT:VALr : -7479
HacL_VPM_LVDT:VALr : 1768
HacL_HPE1313A:0_Ch58 : -0.116211
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.194848
HacL_alignPITCH : -0.140677
HacL_alignHPT : 4.52905
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5094
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2603
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 175
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88