User name adev
Log entry time 19:53:53 on December 1, 2000
Entry number 52663
keyword=Start_Run_1546_Tar=carbon,Type=Other,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1546 at Fri Dec 1 19:53:36 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.77e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.119662
Right Arm Q2 momentum : 0.000278047
Right Arm Q2 gauss meter : 0.0005549
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.9745
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.794437
Right Arm Q3 power supply current : 0.2045
Right Arm Q3 momentum : 0.000513937
Right Arm Q3 gauss meter : 0.0002635
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24304
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.85
Left Arm Q2 momentum : 3.80829
Left Arm Q2 gauss meter : -0.8626
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.29
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.29
Left Arm Q3 momentum : 3.80864
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 29.9164
Current on Unser monitor : 27.2174
Current on Upstream bcm : 29.7602
Current on Downstream bcm : 30.0726
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 35.7457
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.161172
haBDSPOS : 732010
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 18.78
haSC200_6_Sensor_3_R : 3.19
haSC200_6_Sensor_4_R : 40.11
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 83.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 68.6
haITC502_5_Sensor_1_R : 62.76
haITC502_5_Sensor_2_R : 61.86
haITC502_5_Sensor_3_R : 202.1
haITC502_6_Sensor_1_R : 97.91
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.73
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.86875
HacR_HPM_LVDT:VALr : -1333
HacR_VPM_LVDT:VALr : -1746
HacR_HPE1313A:0_Ch58 : -0.564453
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.83252
HacR_alignROLL : -0.351794
HacR_alignPITCH : 0.00713068
HacR_alignHPT : -1.23906
HacL_HPM_LVDT:VALr : -7480
HacL_VPM_LVDT:VALr : 1768
HacL_HPE1313A:0_Ch58 : -0.116699
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.194995
HacL_alignPITCH : -0.140826
HacL_alignHPT : 4.53009
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5094
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2603
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 175
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88