User name adev
Log entry time 21:50:17 on December 1, 2000
Entry number 52674
keyword=Start_Run_1551_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1551 at Fri Dec 1 21:50:05 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.65e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.350211
Right Arm Q2 momentum : 0.000813749
Right Arm Q2 gauss meter : 0.0005532
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.9754
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.30768
Right Arm Q3 power supply current : 0.254491
Right Arm Q3 momentum : 0.000639572
Right Arm Q3 gauss meter : 0.0002675
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.59
Left Arm Q1 momentum : 3.80895
Left Arm Q1 gauss meter : 0.24303
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.9
Left Arm Q2 momentum : 3.8084
Left Arm Q2 gauss meter : -0.8626
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.29
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.29
Left Arm Q3 momentum : 3.80864
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 39.8353
Current on Unser monitor : 40.8101
Current on Upstream bcm : 44.2131
Current on Downstream bcm : 44.5258
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 68.48
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 4.92552
Radiator Encoder : 0.148962
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.53
haSC200_6_Sensor_2_R : 18.35
haSC200_6_Sensor_3_R : 3.19
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.034
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 80.4
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 68.5
haITC502_5_Sensor_1_R : 62.59
haITC502_5_Sensor_2_R : 61.48
haITC502_5_Sensor_3_R : 199.8
haITC502_6_Sensor_1_R : 97.58
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.53
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.86875
HacR_HPM_LVDT:VALr : -1326
HacR_VPM_LVDT:VALr : -1745
HacR_HPE1313A:0_Ch58 : -0.564941
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.83252
HacR_alignROLL : -0.351243
HacR_alignPITCH : 0.00706488
HacR_alignHPT : -1.24721
HacL_HPM_LVDT:VALr : -7499
HacL_VPM_LVDT:VALr : 1767
HacL_HPE1313A:0_Ch58 : -0.116699
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.195363
HacL_alignPITCH : -0.140752
HacL_alignHPT : 4.55226
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5095
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2602
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 202
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88