Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 06:46:55 on December 2, 2000
Entry number 52698
keyword=Start_Run_1559_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1559 at Sat Dec 2 06:46:44 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.84e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.345836
Right Arm Q2 momentum : 0.000803583
Right Arm Q2 gauss meter : 0.000571
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97446
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.784749
Right Arm Q3 power supply current : 0.247088
Right Arm Q3 momentum : 0.000620968
Right Arm Q3 gauss meter : 0.0002553
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24302
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.84
Left Arm Q2 momentum : 3.80828
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.28
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.36
Left Arm Q3 momentum : 3.80881
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 17.0986
Current on Unser monitor : 7.66544
Current on Upstream bcm : 10.1241
Current on Downstream bcm : 24.073
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 53.4415
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00122
Radiator Encoder : 0.161172
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 59.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.56
haSC200_6_Sensor_2_R : 17.55
haSC200_6_Sensor_3_R : 3.24
haSC200_6_Sensor_4_R : 40.16
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.8
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 67.1
haITC502_5_Sensor_1_R : 61.29
haITC502_5_Sensor_2_R : 59.84
haITC502_5_Sensor_3_R : 190.7
haITC502_6_Sensor_1_R : 95.15
haITC502_6_Sensor_2_R : 99.11
haITC502_6_Sensor_3_R : 27.39
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1347
HacR_VPM_LVDT:VALr : -1752
HacR_HPE1313A:0_Ch58 : -0.564453
HacR_HPE1313A:0_Ch55 : 22.7539
HacR_HPE1313A:0_Ch54 : -0.831543
HacR_alignROLL : -0.350257
HacR_alignPITCH : 0.00751379
HacR_alignHPT : -1.22314
HacL_HPM_LVDT:VALr : -7528
HacL_VPM_LVDT:VALr : 1765
HacL_HPE1313A:0_Ch58 : -0.115723
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.156738
HacL_alignROLL : 0.194995
HacL_alignPITCH : -0.141263
HacL_alignHPT : 4.58484
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5093
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.26
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 198
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88