Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 08:47:08 on December 2, 2000
Entry number 52707
keyword=Start_Run_1561_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1561 at Sat Dec 2 08:46:58 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.05e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.334806
Right Arm Q2 momentum : 0.000777955
Right Arm Q2 gauss meter : 0.0005474
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97671
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.769681
Right Arm Q3 power supply current : 0.222857
Right Arm Q3 momentum : 0.000560069
Right Arm Q3 gauss meter : 0.0002591
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24302
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.14
Left Arm Q2 momentum : 3.80896
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.29
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.22
Left Arm Q3 momentum : 3.80841
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 21.9588
Current on Unser monitor : -3.31521
Current on Upstream bcm : 43.8788
Current on Downstream bcm : 0.0387991
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.131868
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.58
haSC200_6_Sensor_2_R : 17.52
haSC200_6_Sensor_3_R : 3.24
haSC200_6_Sensor_4_R : 40.18
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 92.56
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 66.9
haITC502_5_Sensor_1_R : 61.17
haITC502_5_Sensor_2_R : 59.67
haITC502_5_Sensor_3_R : 189
haITC502_6_Sensor_1_R : 94.84
haITC502_6_Sensor_2_R : 98.66
haITC502_6_Sensor_3_R : 27.37
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1350
HacR_VPM_LVDT:VALr : -1756
HacR_HPE1313A:0_Ch58 : -0.56543
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.831543
HacR_alignROLL : -0.350692
HacR_alignPITCH : 0.00744796
HacR_alignHPT : -1.21953
HacL_HPM_LVDT:VALr : -7529
HacL_VPM_LVDT:VALr : 1760
HacL_HPE1313A:0_Ch58 : -0.115723
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.156738
HacL_alignROLL : 0.195509
HacL_alignPITCH : -0.141338
HacL_alignHPT : 4.58571
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5093
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.26
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88