User name adev
Log entry time 01:25:33 on December 3, 2000
Entry number 52760
keyword=Start_Run_1582_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1582 at Sun Dec 3 01:25:13 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018777
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.227
Right Arm Q2 momentum : 0.999674
Right Arm Q2 gauss meter : 0.22544
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 0.976899
Right Arm D1 NMR : 0.362516
Right Arm Q3 power supply current : 398.081
Right Arm Q3 momentum : 0.999522
Right Arm Q3 gauss meter : 0.17782
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.66
Left Arm Q1 momentum : 3.80904
Left Arm Q1 gauss meter : 0.24301
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.04
Left Arm Q2 momentum : 3.80872
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.3
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.18
Left Arm Q3 momentum : 3.80837
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 43.8453
Current on Unser monitor : 40.5865
Current on Upstream bcm : 44.2137
Current on Downstream bcm : 43.4768
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 86.3374
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01587
Radiator Encoder : 0.17094
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 59
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.56
haSC200_6_Sensor_2_R : 17.23
haSC200_6_Sensor_3_R : 3.17
haSC200_6_Sensor_4_R : 40.14
haHe_Omega_DPG_Sensor_R : -0.035
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.77
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 60.62
haITC502_5_Sensor_2_R : 59.13
haITC502_5_Sensor_3_R : 181.4
haITC502_6_Sensor_1_R : 93.79
haITC502_6_Sensor_2_R : 97.37
haITC502_6_Sensor_3_R : 27.26
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1398
HacR_VPM_LVDT:VALr : -1743
HacR_HPE1313A:0_Ch58 : -0.564453
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.830566
HacR_alignROLL : -0.349155
HacR_alignPITCH : 0.00648427
HacR_alignHPT : -1.1664
HacL_HPM_LVDT:VALr : -7549
HacL_VPM_LVDT:VALr : 1774
HacL_HPE1313A:0_Ch58 : -0.115234
HacL_HPE1313A:0_Ch55 : 23.9258
HacL_HPE1313A:0_Ch54 : -0.155762
HacL_alignROLL : 0.195214
HacL_alignPITCH : -0.141924
HacL_alignHPT : 4.6082
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5089
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2598
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 218
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88