    User name adev

    Log entry time 15:39:56 on December 3, 2000

    Entry number 52805

    keyword=End_of_Run_1584
    ****************************
     Run Number: 1584
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
    junk.  HV on 8.0.0 controller was disabled.  re-enable and start another
    run.
    
    
    Time of run = 2.4196127 min
    Av. current (on 3x) = 42.969687 uA
    Av. current (on 1x) = 42.836746 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    6.2189  |    6.2382  |    6.2496
    up-down    (mC)|    0.1102  |    0.0913  |    0.1271
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |         0.0 /mC  |    0.000 Hz  |         0  | 65535   |         0.0 /mC
        2      |         0.0 /mC  |    0.000 Hz  |         0  | 65535   |         0.0 /mC
        3      |      7991.4 /mC  |  343.388 Hz  |     49852  |     1   |      8016.2 /mC
        4      |    825998.8 /mC  |   17.746 Hz  |   5152746  |  2000   |    828562.3 /mC
        5      |         0.0 /mC  |    0.000 Hz  |         0  | 65535   |         0.0 /mC
        output                       344.546 Hz
    Av. deadtime from accepted triggers = 0.0459
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        3      |  342.94464  Hz     |    343.99978 Hz   |  343.38829 Hz
        4      |  35446.389  Hz     |    35558.852 Hz   |  35492.912 Hz
        5      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        output |  0.0  Hz   |    0.0 Hz |   344.546 Hz
    Accepted triggers  =  50020.00000
     Time of run = 2.4196127 min
     Time of run h- = 1.195931 min
     Time of run h+ = 1.196403 min
     1-(sum of time hel + and -)/( run time) = 1.1274e-02
    Rate of Left Arm Pulser for electronic DT  = 0.0
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 0.0
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = -1
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 57819.089
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.186363  Hz         |    0.0 Hz        |  11.186363 Hz
          -        |  0.0  Hz        |    11.186363 Hz       |  11.193252 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0031004         |   0.0031036         | 0.0062740     
       upstream 3x |   0.0031052         |   0.0031084         | 0.0062838     
       upstream 10x|   0.0031197         |   0.0031229         | 0.0063132     
      downstream   |   0.0030460         |   0.0030491         | 0.0061638    
     downstream 3x |   0.0030601         |   0.0030632         | 0.0061925    
     downstream 10x|   0.0030569         |   0.0030601         | 0.0061861    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   5.15796260e-04 
       upstream 3x |   5.14999360e-04 
       upstream 10x|   5.12606930e-04 
      downstream   |   5.08605270e-04 
     downstream 3x |   5.06262960e-04 
     downstream 10x|   5.23132250e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1584 at Sun Dec  3 03:38:02 EST 2000
    Right Arm D1 momentum                    : 1.0007
    Right Arm arm angle                      : 12.5089
    Left Arm D1 momentum                      : 3.8086
    Left Arm arm angle                        : 19.2598
    Tiefenbach Hall A energy                : 4582.72
    Right Arm arm mispointing (HPT)          : -1.16612
    Left Arm arm mispointing (HPT)            : 4.60824
    Right Arm Q1 power supply current        : 752.01
    Right Arm Q1 momentum                    : 1.0001
    Right Arm Q1 gauss meter                 : -0.018768
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.346
    Right Arm Q2 momentum                    : 0.999951
    Right Arm Q2 gauss meter                 : 0.22555
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 343.4
    Right Arm D1 momentum                    : 1.0007
    Right Arm D1 NMR                         : 0.371349
    Right Arm Q3 power supply current        : 397.726
    Right Arm Q3 momentum                    : 0.99954
    Right Arm Q3 gauss meter                 : 0.1778
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2865.52
    Left Arm Q1 momentum                      : 3.80885
    Left Arm Q1 gauss meter                   : 0.24302
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1639.97
    Left Arm Q2 momentum                      : 3.80857
    Left Arm Q2 gauss meter                   : -0.8626
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1400.31
    Left Arm D1 momentum                      : 3.8086
    Left Arm D1 NMR                           : 1.41088
    Left Arm Q3 power supply current          : 1516.29
    Left Arm Q3 momentum                      : 3.80863
    Left Arm Q3 gauss meter                   : 0.7558
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 42.8694
    Current on Unser monitor                : 39.1075
    Current on Upstream bcm                 : 43.3963
    Current on Downstream bcm               : 42.3426
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 42.0169
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.72
    Tiefenbach Hall C energy                : 2323.86
    Delta(E)/E width (MV_AI_DXWID)          : 4.25265
    IPM1C12.XPOS                            : -0.00211525
    IPM1H04A.XPOS                           : 
    IPM1H04A.YPOS                           : 
    IPM1H04B.XPOS                           : 
    IPM1H04B.YPOS                           : 
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.86875
     HacR_HPM_LVDT:VALr                     : -1400
     HacR_VPM_LVDT:VALr                     : -1748
     HacR_HPE1313A:0_Ch58                   : -0.563965
     HacR_HPE1313A:0_Ch55                   : 22.8516
     HacR_HPE1313A:0_Ch54                   : -0.82959
     HacR_alignROLL                         : -0.348662
     HacR_alignPITCH                        : 0.00558642
     HacR_alignHPT                          : -1.16028
     HacL_HPM_LVDT:VALr                     : -7557
     HacL_VPM_LVDT:VALr                     : 1770
     HacL_HPE1313A:0_Ch58                   : -0.115234
     HacL_HPE1313A:0_Ch55                   : 23.9746
     HacL_HPE1313A:0_Ch54                   : -0.15625
     HacL_alignROLL                         : 0.195729
     HacL_alignPITCH                        : -0.142361
     HacL_alignHPT                          : 4.61798
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 59.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 21.97
    haH2_P_Exhaust_R                         : 21.99
    haH2_P_Fill_Bottle_R                     : 22.39
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.571
    haSC200_6_Sensor_1_R                     : 242.65
    haSC200_6_Sensor_2_R                     : 17.27
    haSC200_6_Sensor_3_R                     : 3.22
    haSC200_6_Sensor_4_R                     : 40.16
    haHe_Omega_DPG_Sensor_R                  : -0.034
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 89.44
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.15
    haITC502_4_Sensor_1_R                    : 75.6
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 66.2
    haITC502_5_Sensor_1_R                    : 60.56
    haITC502_5_Sensor_2_R                    : 59.05
    haITC502_5_Sensor_3_R                    : 168.8
    haITC502_6_Sensor_1_R                    : 93.57
    haITC502_6_Sensor_2_R                    : 97.11
    haITC502_6_Sensor_3_R                    : 27.19
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.86875
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 228
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : ON