User name adev
Log entry time 23:18:11 on December 3, 2000
Entry number 52828
keyword=Start_Run_1608_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1608 at Sun Dec 3 23:17:58 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.045
Right Arm Q1 momentum : 1.00015
Right Arm Q1 gauss meter : -0.018771
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.239
Right Arm Q2 momentum : 0.999702
Right Arm Q2 gauss meter : 0.22545
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current :
Right Arm D1 momentum : 1.00072
Right Arm D1 NMR : 0.371356
Right Arm Q3 power supply current : 397.704
Right Arm Q3 momentum : 0.999484
Right Arm Q3 gauss meter : 0.17777
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.49
Left Arm Q1 momentum : 3.80881
Left Arm Q1 gauss meter : 0.24303
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.21
Left Arm Q2 momentum : 3.80912
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.31
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.22
Left Arm Q3 momentum : 3.80845
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0360153
Current on Unser monitor : -4.6263
Current on Upstream bcm : 0.0343838
Current on Downstream bcm : 0.0372403
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 4.95238
Radiator Encoder : 0.15873
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 59.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.71
haSC200_6_Sensor_2_R : 17.18
haSC200_6_Sensor_3_R : 3.21
haSC200_6_Sensor_4_R : 40.18
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.26
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.5
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 66
haITC502_5_Sensor_1_R : 60.55
haITC502_5_Sensor_2_R : 59.08
haITC502_5_Sensor_3_R : 170.5
haITC502_6_Sensor_1_R : 93.66
haITC502_6_Sensor_2_R : 97.18
haITC502_6_Sensor_3_R : 27.17
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.86875
HacR_HPM_LVDT:VALr : -1421
HacR_VPM_LVDT:VALr : -1767
HacR_HPE1313A:0_Ch58 : -0.563477
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.828125
HacR_alignROLL : -0.346082
HacR_alignPITCH : 0.00500572
HacR_alignHPT : -1.14269
HacL_HPM_LVDT:VALr : -7577
HacL_VPM_LVDT:VALr : 1765
HacL_HPE1313A:0_Ch58 : -0.114258
HacL_HPE1313A:0_Ch55 : 24.0723
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.195287
HacL_alignPITCH : -0.143309
HacL_alignHPT : 4.63945
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2596
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88