User name adev
Log entry time 03:21:41 on December 5, 2000
Entry number 52917
keyword=Start_Run_1640_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1640 at Tue Dec 5 03:21:27 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018775
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.41
Right Arm Q2 momentum : 1.0001
Right Arm Q2 gauss meter : 0.22546
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00073
Right Arm D1 NMR : 0.371358
Right Arm Q3 power supply current : 397.703
Right Arm Q3 momentum : 0.999483
Right Arm Q3 gauss meter : 0.17779
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24298
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.9
Left Arm Q2 momentum : 3.80874
Left Arm Q2 gauss meter : -0.8626
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.32
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.26
Left Arm Q3 momentum : 3.80855
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 47.7539
Current on Unser monitor : 43.9694
Current on Upstream bcm : 46.5336
Current on Downstream bcm : 48.9743
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 83.9903
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.78
haSC200_6_Sensor_2_R : 17.27
haSC200_6_Sensor_3_R : 3.27
haSC200_6_Sensor_4_R : 40.23
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.58
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 60.8
haITC502_5_Sensor_2_R : 59.24
haITC502_5_Sensor_3_R : 164.2
haITC502_6_Sensor_1_R : 93.94
haITC502_6_Sensor_2_R : 97.47
haITC502_6_Sensor_3_R : 27.08
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.86875
HacR_HPM_LVDT:VALr : -1426
HacR_VPM_LVDT:VALr : -1761
HacR_HPE1313A:0_Ch58 : -0.562012
HacR_HPE1313A:0_Ch55 : 23.1445
HacR_HPE1313A:0_Ch54 : -0.826172
HacR_alignROLL : -0.344864
HacR_alignPITCH : 0.0038442
HacR_alignHPT : -1.13778
HacL_HPM_LVDT:VALr : -7585
HacL_VPM_LVDT:VALr : 1774
HacL_HPE1313A:0_Ch58 : -0.114258
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.19558
HacL_alignPITCH : -0.143608
HacL_alignHPT : 4.64825
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5087
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2595
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 296
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88