User name adev
Log entry time 17:18:48 on December 5, 2000
Entry number 52950
keyword=Start_Run_1652_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1652 at Tue Dec 5 17:18:38 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018779
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.4
Right Arm Q2 momentum : 1.00007
Right Arm Q2 gauss meter : 0.22553
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.4
Right Arm D1 momentum : 1.00073
Right Arm D1 NMR : 0.371358
Right Arm Q3 power supply current : 397.902
Right Arm Q3 momentum : 0.999984
Right Arm Q3 gauss meter : 0.17778
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.49
Left Arm Q1 momentum : 3.80881
Left Arm Q1 gauss meter : 0.24299
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.16
Left Arm Q2 momentum : 3.80902
Left Arm Q2 gauss meter : -0.8628
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.34
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.33
Left Arm Q3 momentum : 3.80862
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 46.2505
Current on Unser monitor : 44.5554
Current on Upstream bcm : 46.4672
Current on Downstream bcm : 48.4204
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 89.7158
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 4.99145
Radiator Encoder : 0.14652
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.55
haSC200_6_Sensor_2_R : 17.15
haSC200_6_Sensor_3_R : 3.19
haSC200_6_Sensor_4_R : 40.14
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.93
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.4
haITC502_5_Sensor_1_R : 60.42
haITC502_5_Sensor_2_R : 58.95
haITC502_5_Sensor_3_R : 163.4
haITC502_6_Sensor_1_R : 93.73
haITC502_6_Sensor_2_R : 97.23
haITC502_6_Sensor_3_R : 27.03
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868799
HacR_HPM_LVDT:VALr : -1422
HacR_VPM_LVDT:VALr : -1725
HacR_HPE1313A:0_Ch58 : -0.562988
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.82666
HacR_alignROLL : -0.345473
HacR_alignPITCH : 0.00487399
HacR_alignHPT : -1.14191
HacL_HPM_LVDT:VALr : -7593
HacL_VPM_LVDT:VALr : 1820
HacL_HPE1313A:0_Ch58 : -0.115723
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : -0.155273
HacL_alignROLL : 0.196537
HacL_alignPITCH : -0.142373
HacL_alignHPT : 4.65673
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2595
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 225
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88