User name adev
Log entry time 18:43:02 on December 5, 2000
Entry number 52952
keyword=Start_Run_1653_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1653 at Tue Dec 5 18:42:51 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.01878
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.248
Right Arm Q2 momentum : 0.999723
Right Arm Q2 gauss meter : 0.22546
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00073
Right Arm D1 NMR : 0.371358
Right Arm Q3 power supply current : 397.941
Right Arm Q3 momentum : 1.00008
Right Arm Q3 gauss meter : 0.17781
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.42
Left Arm Q1 momentum : 3.80871
Left Arm Q1 gauss meter : 0.24298
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.94
Left Arm Q2 momentum : 3.8085
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.34
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.23
Left Arm Q3 momentum : 3.80848
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.7542
Current on Unser monitor : 45.6318
Current on Upstream bcm : 48.33
Current on Downstream bcm : 49.1784
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 92.75
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.46
haSC200_6_Sensor_2_R : 17.15
haSC200_6_Sensor_3_R : 3.17
haSC200_6_Sensor_4_R : 40.11
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.73
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.3
haITC502_5_Sensor_1_R : 60.75
haITC502_5_Sensor_2_R : 59.21
haITC502_5_Sensor_3_R : 162.9
haITC502_6_Sensor_1_R : 93.85
haITC502_6_Sensor_2_R : 97.35
haITC502_6_Sensor_3_R : 27.03
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868799
HacR_HPM_LVDT:VALr : -1424
HacR_VPM_LVDT:VALr : -1727
HacR_HPE1313A:0_Ch58 : -0.563965
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.826172
HacR_alignROLL : -0.345038
HacR_alignPITCH : 0.00538883
HacR_alignHPT : -1.14328
HacL_HPM_LVDT:VALr : -7600
HacL_VPM_LVDT:VALr : 1821
HacL_HPE1313A:0_Ch58 : -0.115723
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.155273
HacL_alignROLL : 0.196464
HacL_alignPITCH : -0.142298
HacL_alignHPT : 4.66682
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2594
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 215
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88