User name adev
Log entry time 08:57:59 on December 6, 2000
Entry number 52992
keyword=Start_Run_1669_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1669 at Wed Dec 6 08:57:47 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018778
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.606
Right Arm Q2 momentum : 1.00055
Right Arm Q2 gauss meter : 0.22557
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00073
Right Arm D1 NMR : 0.371359
Right Arm Q3 power supply current : 398.072
Right Arm Q3 momentum : 1.00041
Right Arm Q3 gauss meter : 0.17781
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.49
Left Arm Q1 momentum : 3.80881
Left Arm Q1 gauss meter : 0.24301
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.12
Left Arm Q2 momentum : 3.80891
Left Arm Q2 gauss meter : -0.8628
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.34
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 0
Left Arm Q3 power supply current : 1516.36
Left Arm Q3 momentum : 3.8088
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 47.104
Current on Unser monitor : 45.3855
Current on Upstream bcm : 47.3395
Current on Downstream bcm : 47.0193
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 88.0418
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 4.99878
Radiator Encoder : 0.136752
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.35
haSC200_6_Sensor_2_R : 17.17
haSC200_6_Sensor_3_R : 3.12
haSC200_6_Sensor_4_R : 40.08
haHe_Omega_DPG_Sensor_R : -0.033
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.73
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.5
haITC502_5_Sensor_1_R : 60.52
haITC502_5_Sensor_2_R : 59.09
haITC502_5_Sensor_3_R : 158.5
haITC502_6_Sensor_1_R : 93.98
haITC502_6_Sensor_2_R : 97.45
haITC502_6_Sensor_3_R : 26.98
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868896
HacR_HPM_LVDT:VALr : -1426
HacR_VPM_LVDT:VALr : -1704
HacR_HPE1313A:0_Ch58 : -0.563477
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.829102
HacR_alignROLL : -0.347445
HacR_alignPITCH : 0.00442502
HacR_alignHPT : -1.13631
HacL_HPM_LVDT:VALr : -7607
HacL_VPM_LVDT:VALr : 1859
HacL_HPE1313A:0_Ch58 : -0.11377
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.154297
HacL_alignROLL : 0.196906
HacL_alignPITCH : -0.143171
HacL_alignHPT : 4.66996
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5087
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2594
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 225
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88