Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 13:12:34 on December 6, 2000
Entry number 53002
keyword=Start_Run_1674_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1674 at Wed Dec 6 13:12:24 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018773
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.375
Right Arm Q2 momentum : 1.00002
Right Arm Q2 gauss meter : 0.22559
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.4
Right Arm D1 momentum : 1.00073
Right Arm D1 NMR : 0.371359
Right Arm Q3 power supply current : 397.986
Right Arm Q3 momentum : 1.00019
Right Arm Q3 gauss meter : 0.17785
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.49
Left Arm Q1 momentum : 3.80881
Left Arm Q1 gauss meter : 0.243
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.81
Left Arm Q2 momentum : 3.80819
Left Arm Q2 gauss meter : -0.8628
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.33
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.19
Left Arm Q3 momentum : 3.8086
Left Arm Q3 gauss meter : 0.756
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 45.3521
Current on Unser monitor : 42.5681
Current on Upstream bcm : 45.5623
Current on Downstream bcm : 45.1419
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 91.2303
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.02076
Radiator Encoder : 0.15873
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.7
haSC200_6_Sensor_2_R : 17.27
haSC200_6_Sensor_3_R : 3.17
haSC200_6_Sensor_4_R : 40.16
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.07
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 60.69
haITC502_5_Sensor_2_R : 59.25
haITC502_5_Sensor_3_R : 158
haITC502_6_Sensor_1_R : 94.07
haITC502_6_Sensor_2_R : 97.54
haITC502_6_Sensor_3_R : 26.98
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868799
HacR_HPM_LVDT:VALr : -1438
HacR_VPM_LVDT:VALr : -1724
HacR_HPE1313A:0_Ch58 : -0.562012
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.827637
HacR_alignROLL : -0.345908
HacR_alignPITCH : 0.00391012
HacR_alignHPT : -1.12712
HacL_HPM_LVDT:VALr : -7611
HacL_VPM_LVDT:VALr : 1830
HacL_HPE1313A:0_Ch58 : -0.114258
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.155762
HacL_alignROLL : 0.196464
HacL_alignPITCH : -0.143171
HacL_alignHPT : 4.67911
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5087
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2593
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 241
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88