User name adev
Log entry time 07:24:39 on December 7, 2000
Entry number 53059
keyword=Start_Run_1697_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1697 at Thu Dec 7 07:24:26 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.01878
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.197
Right Arm Q2 momentum : 0.999564
Right Arm Q2 gauss meter : 0.22552
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.4
Right Arm D1 momentum : 1.00074
Right Arm D1 NMR : 0.371361
Right Arm Q3 power supply current : 397.894
Right Arm Q3 momentum : 0.999963
Right Arm Q3 gauss meter : 0.17782
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.49
Left Arm Q1 momentum : 3.80881
Left Arm Q1 gauss meter : 0.24298
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.18
Left Arm Q2 momentum : 3.80905
Left Arm Q2 gauss meter : -0.8628
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.34
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.21
Left Arm Q3 momentum : 3.80844
Left Arm Q3 gauss meter : 0.756
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.4106
Current on Unser monitor : 44.9179
Current on Upstream bcm : 47.8809
Current on Downstream bcm : 48.9402
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 95.1051
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.202686
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.4
haSC200_6_Sensor_2_R : 17.2
haSC200_6_Sensor_3_R : 3.09
haSC200_6_Sensor_4_R : 40.06
haHe_Omega_DPG_Sensor_R : -0.034
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.03
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 61.05
haITC502_5_Sensor_2_R : 59.54
haITC502_5_Sensor_3_R : 155.3
haITC502_6_Sensor_1_R : 94.36
haITC502_6_Sensor_2_R : 97.85
haITC502_6_Sensor_3_R : 26.93
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868896
HacR_HPM_LVDT:VALr : -1439
HacR_VPM_LVDT:VALr : -1716
HacR_HPE1313A:0_Ch58 : -0.563965
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.828613
HacR_alignROLL : -0.347503
HacR_alignPITCH : 0.00583777
HacR_alignHPT : -1.12173
HacL_HPM_LVDT:VALr : -7603
HacL_VPM_LVDT:VALr : 1848
HacL_HPE1313A:0_Ch58 : -0.114258
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : -0.154297
HacL_alignROLL : 0.196022
HacL_alignPITCH : -0.143171
HacL_alignHPT : 4.66815
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5086
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2594
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 278
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88