Log entry time 23:29:36 on December 7, 2000
Entry number 53088
keyword=Start_Run_1707_Tar=carbon,Type=Optics,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1707 at Thu Dec 7 23:29:20 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018762
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.381
Right Arm Q2 momentum : 1.00003
Right Arm Q2 gauss meter : 0.22547
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.399
Right Arm D1 momentum : 1.00092
Right Arm D1 NMR : 0.371428
Right Arm Q3 power supply current : 398.124
Right Arm Q3 momentum : 1.00054
Right Arm Q3 gauss meter : 0.17788
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : -0.24249
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1640.1
Left Arm Q2 momentum : 3.80886
Left Arm Q2 gauss meter : 0.8636
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1398.83
Left Arm D1 momentum : 3.80861
Left Arm D1 NMR : 1.41089
Left Arm Q3 power supply current : 1516.23
Left Arm Q3 momentum : 3.80848
Left Arm Q3 gauss meter : -0.7562
Left Arm Q3 power supply polarity : 1
Average current of the two cavities : 45.1552
Current on Unser monitor : 43.8407
Current on Upstream bcm : 44.805
Current on Downstream bcm : 45.5054
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 94.9421
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.153846
haBDSPOS : 2.50445e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.03
haSC200_6_Sensor_2_R : 17.23
haSC200_6_Sensor_3_R : 2.92
haSC200_6_Sensor_4_R : 39.86
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 91.86
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.4
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 61.41
haITC502_5_Sensor_2_R : 59.94
haITC502_5_Sensor_3_R : 160.3
haITC502_6_Sensor_1_R : 95.5
haITC502_6_Sensor_2_R : 99.06
haITC502_6_Sensor_3_R : 26.96
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1418
HacR_VPM_LVDT:VALr : -1629
HacR_HPE1313A:0_Ch58 : -0.562988
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.833008
HacR_alignROLL : -0.352607
HacR_alignPITCH : 0.00558642
HacR_alignHPT : -1.14121
HacL_HPM_LVDT:VALr : -7547
HacL_VPM_LVDT:VALr : 1930
HacL_HPE1313A:0_Ch58 : -0.11377
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.155762
HacL_alignROLL : 0.196244
HacL_alignPITCH : -0.144257
HacL_alignHPT : 4.60547
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2598
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 248
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88