User name adev
Log entry time 02:44:07 on December 8, 2000
Entry number 53099
keyword=Start_Run_1711_Tar=carbon,Type=Optics,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1711 at Fri Dec 8 02:43:54 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018782
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.378
Right Arm Q2 momentum : 1.00003
Right Arm Q2 gauss meter : 0.22556
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00084
Right Arm D1 NMR : 0.371399
Right Arm Q3 power supply current : 397.953
Right Arm Q3 momentum : 1.00011
Right Arm Q3 gauss meter : 0.17788
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21442
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.56
Left Arm Q2 momentum : 3.35942
Left Arm Q2 gauss meter : -0.7616
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1117.01
Left Arm D1 momentum : 3.17477
Left Arm D1 NMR : 1.17569
Left Arm Q3 power supply current : 1337.37
Left Arm Q3 momentum : 3.35924
Left Arm Q3 gauss meter : 0.6667
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.5004
Current on Unser monitor : 45.6393
Current on Upstream bcm : 47.8712
Current on Downstream bcm : 49.1297
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 95.9907
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.153846
haBDSPOS : 732012
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.03
haSC200_6_Sensor_2_R : 17.28
haSC200_6_Sensor_3_R : 2.94
haSC200_6_Sensor_4_R : 39.84
haHe_Omega_DPG_Sensor_R : -0.036
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 92.06
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.7
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 67.6
haITC502_5_Sensor_1_R : 61.57
haITC502_5_Sensor_2_R : 60.08
haITC502_5_Sensor_3_R : 162.5
haITC502_6_Sensor_1_R : 95.64
haITC502_6_Sensor_2_R : 99.26
haITC502_6_Sensor_3_R : 27.15
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1417
HacR_VPM_LVDT:VALr : -1623
HacR_HPE1313A:0_Ch58 : -0.567383
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.841797
HacR_alignROLL : -0.360438
HacR_alignPITCH : 0.00866315
HacR_alignHPT : -1.1401
HacL_HPM_LVDT:VALr : -8155
HacL_VPM_LVDT:VALr : 1366
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 24.0234
HacL_HPE1313A:0_Ch54 : -0.285645
HacL_alignROLL : 0.0803419
HacL_alignPITCH : -0.129409
HacL_alignHPT : 5.33823
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7675
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 259
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88